Raption 150 Compact Service Manual
B
Work in a safe environment
It is recommended to be very cautious and work safely to control all potential electrical
hazards.
So, the safety rules shown below classify the work to be done depeding on the present
electrical risk, that helps to control risks of injury or death from workplace hazards.
ELECTRICAL RISK
SITUATION
Work without voltage
Live working
Proximity
Steps to be followed during the development of the tests
- Work without voltage unless it is strictly necessary.
- If it is necessary to access the equipment while it is connected (with or without load),
measures should be taken to ensure that all conductive elements are properly protected
by appropriate polycarbonates or insulating enclosures.
- If it cannot be guaranteed that ALL live parts of the equipment are protected by
polycarbonates, live working shall be carried out.
- Guarantee safety distance between risk elements (cabinets, dispensers, wallboxes...)
and the work table (computers, readers, testers).
- Wide and safe access from the door of the box to the work areas. There should always
be a safe escape route.
- Minimise the presence of cables in working areas and put cable protectors.
- Remove all the elements that are not essential for carrying out the tests.
- Have the necessary safety signs to be used as required.
03
EQUIPMENT SITUATION
Disconnected
Equipment connected
without load
Equipment connected
under load (up to 1000 V)
Equipment connected
without load
Equipment connected
under load (up to 1000 V)
DESCRIPTION
-
Acting on live elements or
at a distance of less than
70 cm from live elements.
Below the established
safety distance.
Distance greater than 70
cm to live elements.
Need help?
Do you have a question about the Raption 150 Compact CCS and is the answer not in the manual?
Questions and answers