Focpp Errors - Circontrol Raption 150 Compact CCS Service Manual

Table of Contents

Advertisement

F
OCPP Errors
Most common troubles establishing communications with a Central System.
OCPP 1.5
Connect failed in tcp_connect
Common causes:
Host URL introduced is not correct. Check it on OCPP configuration.
Check if DHCP=ON whithin Network section on web page from CP. Reboot
required.
Detail: bind failed in soap_bind /' 'Error 28'
OCPP Listening Ports configured already used by default by the unit: 80, 8080,
65432, 22.
Can not get charge device name
The internal application of charge point is corrupted/lost or is not installed.
It requires to upload a file provided by Circontrol support team within Configuration
Update section on web page of the charge point.
Notifying Boot - 200
CS should check if charger is added in their side.
Check charge point ID whithin OCPP configuration on CP side. http://ip_
address:8080/html/setup.html