RESOLUTE Functional Safety Siemens DRIVE-CLiQ Serial interface

Power supply
Interface over voltage protection −36 V to +36 V
Temperature
Humidity
Sealing
Environment protection
Acceleration
Shock
Non-operating
(readhead and interface)
Maximum acceleration of scale with respect to readhead
Vibration
Mass
Readhead cable
CAUTION: The RESOLUTE encoder system has been designed to meet the requirements of IEC 61800-5-2: Annex E second environment, but must be correctly integrated to achieve EMC compliance.
In particular, attention to shielding arrangements is essential.
1
If the original termination is altered by the user or an extension cable is used, it is the responsibility of the system manufacturer to ensure the IP rating of the interface connection meets their requirements.
2
This is the worst-case figure that is correct for the slowest communications request rates. For faster request rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, contact your
local Renishaw representative.
72
RESOLUTE™ Functional Safety Installation guide and safety manual Siemens DRIVE-CLiQ encoder system
Voltage and current
4.3 W maximum
24 V power is provided by the DRIVE-CLiQ network
Storage
−20 °C to +70 °C
(system)
Installation
20 ±5 °C
(system)
Operating
0 °C to +80 °C
(readhead)
Operating
0 °C to +55 °C
(interface)
(system)
95% relative humidity (non-condensing) to IEC 60068-2-78
(readhead)
IP64
1
(interface)
IP67
Protection class III
Pollution degree II
Altitude 2000 m
Operating
500 m / s
, 3 axes
(readhead)
2
500 m / s
2
, 11 ms, ½ sine, 3 axes
2
2000 m / s
2
Operating
300 m / s
2
max @ 55 Hz to 2000 Hz, 3 axes
(readhead)
Operating
100 m / s
max @ 55 Hz to 2000 Hz, 3 axes
(interface)
2
(readhead)
18 g
(readhead cable)
32 g/m
(interface)
218 g
7 core, tinned and annealed copper, 28 AWG
Single-shielded, outside diameter 4.7 ±0.2 mm
Flex life > 40 × 10
cycles at 20 mm bend radius
6
10 m maximum length (refer to Siemens DRIVE-CLiQ specifications for maximum cable length from interface to controller)
UL recognised component
Original instructions