Installation guide
M-9417-9255-03-B
QUANTiC
RTLC40-S incremental linear encoder system

Advertisement

Table of Contents
loading

Summary of Contents for Renishaw QUANTiC RTLC40-S

  • Page 1 Installation guide M-9417-9255-03-B QUANTiC RTLC40-S incremental linear encoder system ™...
  • Page 2: Table Of Contents

    QUANTiC quick-start guide Readhead mounting and alignment System calibration Restoring factory defaults Switching Automatic Gain Control (AGC) on or off Troubleshooting Output signals Speed Electrical connections Output specifications General specifications RTLC40-S scale specifications Reference mark Limit switches QUANTiC RTLC40-S installation guide...
  • Page 3: Legal Notices

    Renishaw. including interference that may cause undesired operation. The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised Trade marks representative could void the user’s authority to operate the equipment.
  • Page 4: Storage And Handling

    Spirits Solvents Storage Operating Humidity +70 °C +70 °C −20 °C 0 °C Minimum bend radius RTLC40-S – 150 mm 95% relative humidity NOTE: Ensure self-adhesive tape (non-condensing) to is on the outside of bend. IEC 60068-2-78 QUANTiC RTLC40-S installation guide...
  • Page 5: Quantic Readhead Installation Drawing

    2 mounting holes M2.5 through, counterbored Ø3 × 2.3 deep both sides. NOTE: The recommended thread engagement is 5 min (7.5 including counterbore) and the recommended tightening torque is between 0.25 and 0.4 Nm. *    † Extent of mounting faces Dimension from substrate QUANTiC RTLC40-S installation guide...
  • Page 6: Rtlc40-S Scale Installation Drawing

    NOTES: The reference mark selector and limit actuator locations are correct for the readhead orientation shown. External magnetic fields greater than 6 mT, in the vicinity of the readhead, may cause false activation of the limit and reference sensors. Reference mark selector A-9653-0290 QUANTiC RTLC40-S installation guide...
  • Page 7: Rtlc40-S Scale Application

    2 × M2.5 screws Magnet applicator tool (A-9653-0201) Limit magnets (P limit - A-9653-0138, Q limit - A-9653-0139) Reference mark selector magnet* (A-9653-0143)  The reference mark selector magnet is only required for ‘Customer selectable reference mark’ readheads QUANTiC RTLC40-S installation guide...
  • Page 8 Whilst holding the block in place, in a smooth motion, pull down the lever to cut through the scale. Guillotine press block orientation when cutting RTLC40-S scale Guillotine press block Hold the scale in place and close the shears in a smooth motion to cut through the scale. QUANTiC RTLC40-S installation guide...
  • Page 9 NOTE: Scale applicator can be mounted either way round to enable easiest orientation 11. Clean scale using Renishaw scale cleaning wipes or a clean, dry, lint-free cloth. for scale installation.
  • Page 10: End Covers

    Place the datum clamp with cut-out against the scale in the cut-out on the datum clamp, ensuring none at the chosen location. of the adhesive wicks onto the scale surface. Dispensing tips are available. Ensure the adhesive wicks along the entire length of cut-out. QUANTiC RTLC40-S installation guide...
  • Page 11: Reference Mark Selector And Limit Magnet Installation

    The reference mark selector magnet is only required for ‘Customer selectable reference mark’ readheads. For more information refer to QUANTiC series encoder system data sheet (Renishaw part no. L-9517-9778). External magnetic fields greater than 6 mT, in the vicinity of the readhead, may cause false activation of the limit and reference sensors.
  • Page 12: Quantic Quick-Start Guide

    13). Repeat the installation and calibration routine. *  For more details refer to the Advanced Diagnostic Tool ADTi-100 and ADT View software User guide (Renishaw part no. M-6195-9413) and Advanced Diagnostic Tool ADTi-100 and ADT View software Quick-start guide (Renishaw part no. M-6195-9321). †...
  • Page 13: Readhead Mounting And Alignment

    AGC out of normal operating range Green Orange flashing (analogue flashing flashing flashing variant only) *  ‘Troubleshooting’, page 14 for more information on diagnosing faults. Roll Pitch 0° ±0.8° 0° ±1° Green spacer Rideheight 2.1 ± 0.2 mm QUANTiC RTLC40-S installation guide...
  • Page 14: System Calibration

    To exit the calibration routine at any stage cycle the power to the readhead or connect the ‘Remote CAL’ output pin to 0 V for < 3 seconds. The LED will then stop flashing. Settings stored Blue single flashing None, restore factory defaults and recalibrate Blue double flashing Incremental only Blue (auto-complete) Incremental and reference mark QUANTiC RTLC40-S installation guide...
  • Page 15: Restoring Factory Defaults

    The AGC is automatically enabled once the system has been calibrated (indicated by a Blue LED). AGC can be manually switched off by connecting the ‘Remote CAL’ output pin to 0 V for > 3 seconds < 10 seconds. The LED will then be solid Green. NOTE: AGC can be switched on or off using the optional ADTi-100 and ADT View software. See www.renishaw.com/adt for more information. QUANTiC RTLC40-S installation guide...
  • Page 16: Troubleshooting

    Ensure you are moving the readhead past your chosen reference mark several times even after moving it past the Check the readhead/selector magnet orientation reference mark several times Check the readhead optical window and scale are clean and free from contamination QUANTiC RTLC40-S installation guide...
  • Page 17 Check output signal termination (page 18) When using with ADTi-100 in stand-alone mode ensure Termination tool is connected, Renishaw part number A-6195-2132 Exit CAL mode and restore factory defaults (page 13) Check readhead set-up and alignment (page 11) QUANTiC RTLC40-S installation guide...
  • Page 18: Output Signals

    ‡  Pack of 5 14-way JST SH mating sockets: Setup Clear A-9417-0024 - Bottom mount; Remote CAL * Orange A-9417-0026 - Side mount. Maximum of 20 insertion cycles for JST connector. Shield Screen Case Case Ferrule QUANTiC RTLC40-S installation guide...
  • Page 19: Speed

    0.181 9.06 4.53 0.91 0.45 0.18 0.091 0.045 1038 Analogue readheads Maximum speed: 20 m/s (−3dB) † *  For a readhead with a 1 m cable.   † If the speed exceeds 20 m/s, SDE performance cannot be guaranteed. QUANTiC RTLC40-S installation guide...
  • Page 20: Electrical Connections

    Digital Readhead cable Output signals Dependent on cable type, readhead cable length and Maximum extension clocked output option. Contact your local Renishaw cable length representative for more information. Shield Readhead to ADTi-100 IMPORTANT: The shield should be connected to the machine earth (Field Ground).
  • Page 21: Output Specifications

    Reference 0.8 to 1.2 Vpp NOTE: A wide reference mark option, outputting a reference pulse for the duration of the signal 45° period is available. Contact your local Renishaw † Bi-directionally repeatable. representative for more information. Differential pulse V centred on 45°.
  • Page 22: General Specifications

    Analogue output Digital output < ±120 nm < ±80 nm CAUTION: Renishaw encoder systems have been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. QUANTiC RTLC40-S installation guide...
  • Page 23: Rtlc40-S Scale Specifications

    Customer placed at desired locations Repeatability <  0.1 mm *  For lengths > 2 m FASTRACK ™ carrier with RTLC40 is recommended. Refer to QUANTiC ™ RTLC40 / FASTRACK ™ incremental linear encoder system installation guide (Renishaw part no. M-9417-9248). QUANTiC RTLC40-S installation guide...
  • Page 24 New Mills, Wotton-under-Edge uk@renishaw.com Gloucestershire, GL12 8JR United Kingdom www.renishaw.com *M-9417-9255-03* For worldwide contact details, visit www.renishaw.com/contact Renishaw plc. Registered in England and Wales. Company no: 1106260. Part no.: M-9417-9255-03-B Registered office: New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR, UK. Issued: 02.2021...