Fitting the end covers

The end cover kit is designed to be used with the RTLA30-S scale to provide protection for
exposed scale ends.
NOTE: The end covers can be fitted before or after the readhead is installed.
1. Remove the backing tape from the adhesive tape on the back of the end cover.
2. Align markers on the edges of the end cover with the end of the scale and place the end
cover over the scale.
NOTE: There will be a gap between the end of the scale and the adhesive tape on the
end cover.
Original instructions
Gap

Fitting the datum clamp

IMPORTANT: Allow 24 hours after scale application before fitting the datum clamp.
The datum clamp fixes the RTLA30-S scale rigidly to the substrate at the location chosen.
CAUTION: The metrology of the system may be compromised if the datum clamp is not used.
It can be positioned anywhere along the axis depending upon the customers' requirements.
1. Remove the backing paper from the datum clamp.
2. Place the datum clamp with cut-out against the scale at the chosen location.
3. Place a small amount of adhesive (Loctite
ensuring none of the adhesive wicks onto the scale surface. Dispensing tips for the adhesive
are available.
®
435
) in the cut-out on the datum clamp,
Ensure the adhesive wicks along
the entire length of cut-out.