Renishaw RGH25F Installation Manual

Renishaw RGH25F Installation Manual

Encoder system
Hide thumbs Also See for RGH25F:

Advertisement

Installation guide
M-9562-0001-05-C
RGH25F encoder system

Advertisement

Table of Contents
loading

Summary of Contents for Renishaw RGH25F

  • Page 1 Installation guide M-9562-0001-05-C RGH25F encoder system...
  • Page 2 The RG2 encoder system conforms to the relevant harmonised European standards for electromagnetic compatibility as detailed below. BS EN 61000 BS EN 55011 Patents Features of Renishaw’s encoder systems and similar products are the subjects of the following patents and patent applications: US 4959542 EP 0383901...
  • Page 3: System Description

    Alarm output The REF interface asserts the alarm output (E) for the following conditions:- The RGH25F encoder system consists of a common readhead in standard or UHV compatible form, Incremental signal level below 20% coupled to the interface, which gives accurate, industry standard outputs. There are 10 versions of the Incremental signal level above 135% REF interface, offering digital resolutions of 5 µm to 5 nm, and an analogue version giving 1 Vpp output.
  • Page 4: Reference Mark Phasing

    A limit switch signal is output when the readhead sensor passes over the magnetic actuator. Red Orange Blank NOTE: Reference mark flashes only For full output specification refer to RGH25F Data sheet (L-9517-9113). occur up to 100 mm/s traverse speed.
  • Page 5 RGH25F Installation drawing Dimensions and tolerances in mm. Arrow indicates forward direction of readhead relative to scale Fixing screws M3 x 0.5 x 8 11.5* Alternative mounting face 13.5 Mounting face (Yaw tol. ±0.5°) > 4 (Extent of mounting faces) >R20 dynamic bend radius...
  • Page 6: Electrical Connections

    Pin 15 NOTE: Inner shield must be NOTE: Maximum cable length of 5 m connected to 0V at between RGH25F and REF customer electronics only NOTE: Maximum extension cable length: - analogue output (REF0000) - 100 m - digital outputs, see table below...
  • Page 7: General Operating Specifications

    2.25 Vpp @ 100% signal amplitude centred on 1.65 V not vacuum compatible. The RGH25F series readheads have been designed to the relevant EMC standards (BS EN 61000 BS EN 55011), but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding and earthing arrangements is essential.
  • Page 8 0400 - 50 nm 1000 - 20 nm 2000 - 10 nm 4000 - 5 nm Interface series * Binary interpolation factors from x4 to x4096 also available NOTE: Not all combinations are valid. Check valid options online at www.renishaw.com/epc...
  • Page 9 *M-9562-0001-05* RENISHAW ® and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other countries. apply innovation is a trademark of Renishaw plc.  2003-2008 Renishaw plc All rights reserved Issued 0808...

Table of Contents