Readhead set-up
Ensure that the scale, readhead optical window and mounting face are clean and free
from obstructions.
NOTE: When cleaning the readhead and scale apply cleaning fluid sparingly, do not soak.
To set nominal rideheight, place the readhead spacer with the 'L' shaped aperture under the
optical centre of the readhead to allow normal LED function during set-up procedure. Adjust the
readhead to maximize the signal strength around the full axis rotation or full length of axis to
achieve a green or blue LED.
NOTES:
Flashing of set-up LED indicates scale reading error. The flashing state is latched; remove
power to reset.
The optional Advanced Diagnostic Tool ADTa-100
can be used to aid installation. The ADTa-100 and ADT View software are only compatible
with RESOLUTE readheads showing the
representative for other readhead compatibility.
RESOLUTE readhead shown with REXA ring
1
For more details refer to the Advanced Diagnostic Tools and ADT View software User guide
(Renishaw part no. M-6195-9413).
2
The software can be downloaded for free from www.renishaw.com/adt.
3
For RTLA30/ FASTRACK systems use the 0.6 mm red spacer
4
0.6 ±0.12 mm for the RTLA30/ FASTRACK system
5
The LED is activated regardless of whether the corresponding messages have been reconfigured.
6
The colour depends upon the LED status when component recognition is activated via p0144=1.
Original instructions
1
(A-6525-0100) and ADT View software 
mark. Contact your local Renishaw
RESOLUTE readhead and DRIVE-CLiQ interface status LEDs
Signal %
> 95
> 70 to 95
Colour
Blue
Green
RESOLUTE readhead
Roll
0° ±0.5°
0.8 mm blue spacer
3
REXA ring
2
DRIVE-CLiQ interface RDY LED functions
Colour
Status
-
Off
Green
Continuous light
Orange
Continuous light
Red
Continuous light
Green/ orange or
Flashing light
red/ orange
> 50 to 70
≤ 50
Orange
Red
DRIVE-CLiQ interface
Yaw
0° ±0.5°
Pitch
0° ±0.5°
Rideheight
0.8 ±0.15 mm
4
Description
Power supply is missing or outside of permissible
tolerance range
The component is ready for operation and cyclic
DRIVE-CLiQ communication is taking place
DRIVE-CLiQ communication is being established
At least one fault is present in this component
Component recognition via LED is activated (p0144)
www.renishaw.com