Renishaw QUANTIC RESM40 Installation Manual

Renishaw QUANTIC RESM40 Installation Manual

Angle encoder system
Hide thumbs Also See for QUANTIC RESM40:

Advertisement

Quick Links

Installation guide
M-9417-9201-01-A
QUANTiC
RSLM high accuracy linear encoder
RESM40 angle encoder system

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QUANTIC RESM40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Renishaw QUANTIC RESM40

  • Page 1 Installation guide M-9417-9201-01-A QUANTiC RSLM high accuracy linear encoder RESM40 angle encoder system ™...
  • Page 2: Table Of Contents

    Selecting a mounting option Taper mount method Interference fit method QUANTiC quick-start guide Readhead mounting and alignment System calibration Troubleshooting QUANTiC: Readhead dimensions Output signals Speed Electrical connections Output specifications General specifications RESM40 ring specifications QUANTiC RESM40 angle encoder system installation guide...
  • Page 3: Product Compliance

    INACCURACIES IN THIS DOCUMENT. received, including interference that may cause undesired operation. The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised representative could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, The packaging of our products contains the following materials and can be recycled.
  • Page 4: Storage And Handling

    Ring and readhead Ring only Readhead only 95% relative humidity Operating (non-condensing) Acetone Acetone N-heptane to EN 60068-2-78 +70 °C 0 °C Chlorinated Chlorinated COCH COCH Solvents Solvents Propan-2-ol Methylated Methylated CHOHCH Spirits Spirits QUANTiC RESM40 angle encoder system installation guide...
  • Page 5 510.00 ØDO There are no tapped holes on the 489 mm ring. NOTE: θ is the angle between one tapped hole and the adjacent clearance hole. The angle between two clearance holes is 2θ. QUANTiC RESM40 angle encoder system installation guide...
  • Page 6 180.00 θ Section A–A 2.5 × 45° R0.5 ØDI ØDH ØDO NOTE: θ is the angle between one tapped hole and the adjacent clearance hole. The angle between two clearance holes is 2θ. QUANTiC RESM40 angle encoder system installation guide...
  • Page 7: ('A' Section)

    83.85 238.85 83.65 238.65 98.85 283.85 98.65 283.65 DO = Nominal external diameter. Recommended surface finish ≤Ra 1.2. NOTE: It is recommended that the mounting surface is a turned, rather than ground finish. QUANTiC RESM40 angle encoder system installation guide...
  • Page 8 (less than 0.5 Nm). NOTE: You may notice that the torque required to achieve the radial displacement tolerance will be slightly higher during step 3 than during step 2. This is normal. QUANTiC RESM40 angle encoder system installation guide...
  • Page 9: Interference Fit Method

    209.060 209.031 Excessive tightening of screws can have a small effect on accuracy. Please contact your local representative for 235.060 235.031 more details. 280.066 280.034 330.073 330.037 392.073 392.037 QUANTiC RESM40 angle encoder system installation guide...
  • Page 10: Quantic Quick-Start Guide

    For more details refer to the ‘Advanced Diagnostic Tool ADTi-100 and ADT View software quick start guide’ (M-6195-9321) and ‘Advanced Diagnostic Tool ADTi-100 and ADT View software user guide’ (M-6195-9413). † The software can be downloaded for free from www.renishaw.com/adt. QUANTiC RESM40 angle encoder system installation guide...
  • Page 11: Readhead Mounting And Alignment

    ™ reference mark is integrated in the scale, radially aligned with the centre of the mounting Rideheight hole to the left of the ‘Renishaw’ logo within ±0.5 mm. No external actuators or physical adjustment 2.1 ± 0.15 mm are required.
  • Page 12: System Calibration

    NOTE: System calibration, restoring factory defaults, and enabling/disabling AGC functions can also be carried out using the optional ADTi-100 and ADT View software. See www.renishaw.com/adt for When re-installing the system, or in the case of continued calibration failure, factory defaults should more information.
  • Page 13: Troubleshooting

    Check the readhead optical window and scale are clean and free from contamination even after moving it past the reference mark several times Check the readhead is configured for ‘All reference marks’ to be output QUANTiC RESM40 angle encoder system installation guide...
  • Page 14 The reference mark is not phased Clean the scale and readhead optical window and check for scratches then recalibrate the system ensuring over the reference mark both step 1 and step 2 are completed (see page 10) QUANTiC RESM40 angle encoder system installation guide...
  • Page 15: Readhead Dimensions

    0.25 and 0.4 Nm. 11.5 (Pitch tol. ±1°) Calibration rideheight: 2.1 ±0.15 Forward direction of ring Operating rideheight: 2.1 ±0.2 (increasing count) Extent of mounting faces QUANTiC RESM40 angle encoder system installation guide...
  • Page 16: Output Signals

    Angular speed depends on ring diameter – use the following equation to convert to rev/min. Angular speed (rev/min) = V × 1000 × 60 Where V = maximum linear speed (m/s) and D = external diameter of RESM40 ring (mm) π QUANTiC RESM40 angle encoder system installation guide...
  • Page 17: Electrical Connections

    – Readhead speed too high for reliable operation >15 ms 100R E− or 3-state alarm 100nF Differentially transmitted signals forced open circuit for >15 ms when alarm conditions valid. Inverse signals not shown for clarity QUANTiC RESM40 angle encoder system installation guide...
  • Page 18: General Specifications

    Maximum readhead cable length *Extension cables available. Contact your local Renishaw representative for further details Renishaw encoder systems have been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential.
  • Page 19 RENISHAW ® and the probe symbol used in the RENISHAW logo are registered trade marks of Renishaw plc in the United Kingdom and other countries. *M-9417-9201-01* apply innovation and names and designations of other Renishaw products and technologies are trade marks of Renishaw plc or its subsidiaries.

Table of Contents