REXA30 ring installation drawing

Dimensions and tolerances in mm
10 ±0.1
1
0.25
Scale centreline
D2
D1
D3
2
2
2
Section A-A
1
Graduations are centered within this dimension.
2
The dimensions D1, D2, D3 and D4 for the REXA rings are listed on the following page.
Original instructions
The scale zero is radially aligned with the centre of
the mounting hole to the left of the 'Renishaw' logo
Fiducial marks, 4 positions, to aid installation
Ring rotation to give
increasing count
A
θ
N holes Ø6 through, equally spaced
A
D4
2
www.renishaw.com