Rtla30/Fastrack Scale System Technical Specifications - Renishaw RESOLUTE DRIVE-CLiQ Installation Manual

Table of Contents

Advertisement

RTLA30/FASTRACK scale system technical specifications

RTLA30 scale
Form (height × width)
Mounting
Datum fixing
Material
Installation temperature
Operating temperature range
Accuracy (at 20 °C)
Coefficient of thermal expansion (at 20 °C)
Maximum length
50 nm resolution readhead 13.42 m
1 nm resolution readhead 17.18 m
Mass
FASTRACK carrier
Form (height × width)
Mounting
Material
Installation temperature
Operating temperature range
Coefficient of thermal expansion (at 20 °C)
Maximum supplied length
Minimum recommended length
Mass
60
RESOLUTE™ Functional Safety Installation guide and safety manual Siemens DRIVE-CLiQ encoder system
0.2 mm × 8 mm
Held within the FASTRACK carrier
Loctite
435
(P-AD03-0012)
®
Hardened and tempered martensitic stainless steel
20 ±5 °C
0 to 80 °C
±5 μm/m, calibration traceable to International Standards
10.1 ±0.2 μm/m/°C
12.2 g/m
0.4 mm × 18 mm (includes adhesive)
Self-adhesive backing tape
Hardened and tempered matensitic stainless steel
20 ±5 °C
0 to 80 °C
10.1 ±0.2 μm/m/°C
25 m
100 mm
172 g/m