7. Create a scale datum. Using dispensing tip apply Loctite 435 between scale and FASTRACK
so it wicks underneath the scale and FASTRACK adjacent to the user selected datum
location as shown below.
NOTE: Only apply Loctite 435 in the locations shown below. Loctite 435 has been carefully
selected as it will wick under the scale to lock it to the substrate. Dispensing tips are available.
NOTE: Mechanical datum clamp also available. Contact your local Renishaw representative for
more details.
Original instructions
8. Fix the self-adhesive end covers ensuring a gap of at least 1 mm.
NOTE: End covers must be fitted to ensure that the encoder system adheres to Functional
Safety guidelines.
Ensure a gap > 1 mm
9. Clean the FASTRACK and the scale using a lint-free cloth.