Installing the adhesive mounted RELA30/RSLA30 scale

1. Thoroughly clean and degrease the substrate with a lint-free cloth and clean the underside of
the scale using approved solvents (see
2. Mark the area for epoxy on the adhesive tape and cut the tape accordingly. The epoxy datum
clamp fixes the scale rigidly to the substrate at the chosen location.
52
RESOLUTE™ Functional Safety Installation guide and safety manual Siemens DRIVE-CLiQ encoder system
'Storage and handling'
on page 19).
3. Remove the backing liner from one side of the adhesive tape and stick it to the underside of
the scale.
4. Thoroughly mix and apply the epoxy to the back of the scale and then remove the remaining
backing liner.