Rtla30-S Scale Technical Specifications - Renishaw RESOLUTE DRIVE-CLiQ Installation Manual

Table of Contents

Advertisement

RTLA30-S scale technical specifications

Form (height × width)
Mounting
Datum fixing
Material
Installation temperature
Operating temperature range
Accuracy (at 20 °C)
Coefficient of thermal expansion (at 20 °C)
Maximum length
50 nm resolution readhead 13.42 m
1 nm resolution readhead 17.18 m
Mass
54
RESOLUTE™ Functional Safety Installation guide and safety manual Siemens DRIVE-CLiQ encoder system
0.4 mm x 8 mm (including adhesive)
Adhesive backing tape (nominal thickness 0.2 mm)
Datum clamp (A-9585-0028) secured with Loctite
Hardened and tempered martensitic stainless steel
20 ±5 °C
0 to 80 °C
±5 μm/m, calibration traceable to International Standard
10.1 ±0.2 μm/m/°C
184 g/m
®
435
(P-AD03-0012)