Safety function

The RESOLUTE Functional Safety Siemens DRIVE-CLiQ encoder system shall provide a safe
position when requested by the controller.
The following restrictions apply to this claim:
The maximum request rate supported is 16 kHz.
The RESOLUTE Functional Safety Siemens DRIVE-CLiQ encoder system can support:
Resolution
Maximum scale length (L) with 34 bit position word
Maximum scale length (L) with 28 bit position word
The RESOLUTE Functional Safety Siemens DRIVE-CLiQ encoder system shall allow
electrical errors to be detected by the controller at least for:
Linear systems: electrical error exceeding 600 μm
Rotary systems: electrical error exceeding 1.5°
Provided it is installed correctly, the RESOLUTE Functional Safety Siemens DRIVE-CLiQ
encoder system shall have:
Linear systems: mechanical error not exceeding ±1 mm
Rotary systems: mechanical error not exceeding ±2.5°, refer to page
and page 25
(RESA) or page
38
Any thermal expansion effects of the scale are excluded from the accuracy of the safe position.
The controller checks whether the obtained position data lie in the position window
expected by the controller. Unexpected position data include position jumps and incorrect
direction of travel.
When errors are detected by the controller it is the responsibility of the system manufacturer
to introduce appropriate safety measures e.g. safe stop etc.
The machine controller that interfaces to the RESOLUTE Functional Safety encoder must
have its Functional Safety functions enabled (as often it is a configuration parameter to turn
on Functional Safety functionality), as this is necessary for the RESOLUTE Functional Safety
to be valid.
12
RESOLUTE™ Functional Safety Installation guide and safety manual Siemens DRIVE-CLiQ encoder system
1 nm
17.18 m
N/A
24
(REXA)
The system manufacturer must ensure that the scale and the readhead are mounted securely
and cannot become detached from their mounting points e.g. a bracket fails.
It is the responsibility of the machine builder to validate the safety functions of
the RESOLUTE Functional Safety Siemens DRIVE-CLiQ encoder system in the
specific application.
The system manufacturer must perform a verified commissioning test during installation.
The system repairer must perform a verified commissioning test following replacement of a
50 nm
system part.
N/A
13.42 m
Fault exclusions
The following actions will invalidate the Functional Safety certification of the RESOLUTE
Functional Safety system:
Faults caused by cutting and reconnecting the readhead cable or extending the
readhead cable.
Incorrect installation of the readhead.
Incorrect installation of the rotary or linear scale.
Failure to follow the instructions contained within this installation manual.
Dismantling of the RESOLUTE readhead or the Siemens DRIVE-CLiQ interface.
Operating the system outside of the limits specified within this installation manual.
Original instructions