Linear RESOLUTE readhead installation drawing – standard cable outlet
Dimensions and tolerances in mm
1
Extent of mounting faces.
2
The recommended thread engagement is 6 mm minimum (9 mm including counterbore)
and the recommended tightening torque is 0.9 Nm to 1.1 Nm.
3
Offset and rideheight vary depending upon scale type:
Scale type
Offset
RELA30/ RSLA30
0.8 ±1
RTLA30-S
4.25 ±1
RTLA30/FASTRACK
0.75 ±1
16.5
6.4
17.2
7.8
Offset 0.8 ±1
3
NOTE: RESOLUTE readhead shown on RELA30 spar scale.
Original instructions
Rideheight
0.8 ±0.15
0.8 ±0.15
0.6 ±0.12
R > 20 dynamic bend radius
R > 10 static bend radius
(Roll tolerance ±0.5°)
0.05
Scale and optical centreline
(Yaw tolerance ±0.5°)
0.31
6.5 minimum
36
18
12
14
3
Set-up LED
2 mounting holes M3 through,
counterbored each side, 3 deep
10
1
6
1
Rideheight 0.8 ±0.15
(Pitch tolerance ±0.5°)
0.31
Optical centreline
www.renishaw.com
2
3
47