Download Print this page

Chapter 8 Operation; Operating States - Pilz PMCprotego S1 Operating Manual

Advertisement

8
Operation
8.1

Operating states

8- Betrieb_Zustaende
Operating states
8100
Operating states
8.1
CONFIG
POWER ON
SS1
8-2
The safety card is always in clearly defined operating states.
Download
configuration
Demand
upon
Configurator
Error
STO
STO
Limit values
Error
SS1 Activate
POWER ON
The supply voltages are present.
Transition to STO once the supply voltages are applied
CONFIG
Download of configuration to the safety card
Transition to state of NORMAL OPERATION: Configuration down-
loaded without error
Transition to state of STO: Incorrect configuration data
The motor is switched volt free in the CONFIG operating state (STO is
active)
NORMAL OPERATION
No safety function activated
Transition to state of STO: Internal error
Transition to SAFE OPERATION: A safety function is activated
SAFE OPERATION
Safe operation after at least one safety function has been activated
Transition to STO: Internal error
Transition to SS1 due to
– Error
– Violation of limit values
– Demand upon safety function SS1
Transition to NORMAL OPERATION: No safety function activated
NORMAL
OPERATION
Reset
Error
Safety
function
deactivated
Internal error
SAFE
OPERATION
Safety
function
activated

Advertisement

loading