Remc2 Data Bit Counter Register - Epson S1C17W03 Technical Manual

Cmos 16-bit single chip microcontroller
Table of Contents

Advertisement

Before the counter can start counting by this bit, the REMDBCTL.MODEN bit must be set to 1.
While the counter is running, writing 0 to the REMDBCTL.PRUN bit stops count operations. When
the counter stops by occurrence of a compare DB in one-shot mode, this bit is automatically cleared to 0.
Bits 7–5
Reserved
Bit 4
REMOINV
This bit inverts the REMO output signal.
1 (R/W): Inverted
0 (R/W): Non-inverted
For more information, see Figure 17.4.3.1.
Bit 3
BUFEN
This bit enables or disables the compare buffers.
1 (R/W): Enable
0 (R/W): Disable
For more information, refer to "Continuous Data Transmission and Compare Buffers."
Note: The REMDBCTL.BUFEN bit must be set to 0 when setting the data signal duty and cycle for
the first time.
Bit 2
TRMD
This bit selects the operation mode of the 16-bit counter for data signal generation.
1 (R/W): One-shot mode
0 (R/W): Repeat mode
For more information, refer to "REMO Output Waveform, Data signal."
Bit 1
REMCRST
This bit issues software reset to the REMC2.
1 (W):
Issue software reset
0 (W):
Ineffective
1 (R):
Software reset is executing.
0 (R):
Software reset has finished. (During normal operation)
Setting this bit resets the REMC2 internal counters and interrupt flags. This bit is automatically
cleared after the reset processing has finished.
Note: After the data signal is output in one-shot mode, set the REMDBCTL.REMCRST bit to 1.
Bit 0
MODEN
This bit enables the REMC2 operations.
1 (R/W): Enable REMC2 operations (The operating clock is supplied.)
0 (R/W): Disable REMC2 operations (The operating clock is stopped.)
Note: If the REMDBCTL.MODEN bit is altered from 1 to 0 while sending data, the data being sent
cannot be guaranteed. When setting the REMDBCTL.MODEN bit to 1 again after that, be
sure to write 1 to the REMDBCTL.REMCRST bit as well.

REMC2 Data Bit Counter Register

Register name
Bit
REMDBCNT
15–0 DBCNT[15:0]
Bits 15–0 DBCNT[15:0]
The current value of the 16-bit counter for data signal generation can be read out through these bits.
S1C17W03/W04 TECHNICAL MANUAL
(Rev. 1.2)
Bit name
Initial
0x0000
Seiko Epson Corporation
17 IR REMOTE CONTROLLER (REMC2)
Reset
R/W
H0/S0
R
Cleared by writing 1 to the
REMDBCTL.REMCRST bit.
Remarks