D Troubleshooting For The Terminal Mode Operation - Icom IC-905 Advanced Manual

All mode transceiver
Hide thumbs Also See for IC-905:
Table of Contents

Advertisement

12
ABOUT THE DV GATEWAY FUNCTION
Troubleshooting

D Troubleshooting for the Terminal mode operation

The following chart is designed to help you correct problems which are not equipment malfunctions�
If you are unable to locate the cause of a problem or solve it through the use of this chart, contact your Icom Dealer
or Service Center�
Problem
After your call, the repeater does
not return a status reply�
After your call, the repeater
replies "UR?," Your own call sign
(MY) and ID suffix "G."
After your call, the repeater
replies "RX" or "RPT?" and Your
own call sign (MY) and ID suffix
"G�"
After your call, the repeater
replies 'RPT?' and the access
repeater's call sign�
Possible Cause
Transceiver connection is wrong�
"Allowed Call Sign" is set to "Enable�"
When using the External Gateway
function, you did not click (touch)
<Start>
in the RS-MS3W or
RS-MS3A�
The call was successfully sent, but no
station immediately replied�
Your call sign (MY) has not been
registered at a gateway server�
The Terminal/AP call sign that is
set in the transceiver, RS-MS3A, or
RS-MS3W has not been registered in
the RS-RP3C as the access point�
The destination station's call sign (UR)
has not been registered to the gateway
server, or the registered contents do
not match your transceiver's setting�
The destination station that uses the
Terminal mode or Access Point mode
does not transmit periodically�
The repeater cannot connect to the
destination repeater�
The repeater is busy�
12-23
Solution
When using the Internal Gateway
function, check the connection
between the transceiver and the
router�
When using the External Gateway
function, check the connection
between the transceiver and the
Windows or the Android device�
When using the Internal Gateway
function, set "Allowed Call Sign" to
"Disable" in the INTERNAL GATEWAY
SETTINGS screen�
When using the External Gateway
function, set "Allowed Call sign"
to "Disable" in the RS-MS3W or
RS-MS3A�
Click (touch) <Start>
in the
RS-MS3W or RS-MS3A�
Wait for a while, and try again�
Register your call sign (MY) at a
gateway server�
When using the Internal Gateway
function, register the Terminal/AP call
sign that is set in the transceiver in the
RS-RP3C as the access point�
When using the External Gateway
function, register the Terminal/AP
call sign that is set in the RS-MS3A
or RS-MS3W in the RS-RP3C as the
access point�
Check the destination station's
register information�
The destination station makes a call
again�
Wait for a while, and try again�
REF.
p� 12-11
pp� 12-13,
12-14
p� 12-12
RS-MS3W,
RS-MS3A's
instruction
manual
p� 10-5
p� 10-5

Advertisement

Table of Contents
loading

Table of Contents