Scan Set Screen - Icom IC-905 Advanced Manual

All mode transceiver
Hide thumbs Also See for IC-905:
Table of Contents

Advertisement

7
SCANS

SCAN SET screen

You can change the recorder settings on this screen�
1� Display the SCAN screen�
» SCAN
2� Touch [SET]�
3� Touch the item to set� (Example: SCAN Speed)
4� Touch the option to set� (Example: Slow)
5� To close the SCAN SET screen, push
TIP: You can set each item to its default by touching
the item for 1 second, and then touching "Default" on
the QUICK MENU screen�
SCAN Speed
Sets the desired scan speed to slow or fast�
• Slow: Scan speed is slow�
• Fast: Scan speed is fast�
SCAN Resume
Sets the Scan Resume function to ON or OFF�
• OFF: When a signal is detected, cancels the scan�
• ON: When a signal is detected, the scan pauses
for 10 seconds, then resumes�
Two seconds after the signal disappears, the
scan resumes�
Pause Timer
When Scan Resume is ON, selects the Scan Pause
Timer� When a signal is received, the scan pauses for
this set period of time�
• 2 ~ 20sec: When a signal is received, the scan
• HOLD:
Resume Timer
Selects the scan Resume Timer� When a received
signal disappears, the scan resumes after this set
period of time passed�
• 0sec:
• 1 ~ 5sec: The scan resumes 1 ~ 5 seconds after
• HOLD:
Temporary Skip Timer
Selects the effective time of the Temporary Skip
function�
L This timer is activated for the VFO scan, Memory scan,
• 5min/10min/15min:
• While Scanning:
• While Powered ON:
MAIN DIAL Operation (SCAN)
Selects the function of while scanning�
• OFF:
(Default: Fast)
• Up/Down: Rotating changes the scanning direction�
Program Scan Edge
You can delete, copy, or edit the lower and higher
frequencies for programmed scans�
(Default: ON)
The transceiver has a total of up to 25 frequency
ranges (00 ~ 24), and you can set the scan name,
mode, and the IF filter for each Scan Edge.
L The default setting may differ, depending on the
L See page 7-6 for entering Scan Edges�
7-4
pauses for 2 ~ 20 seconds (in 2 second
steps)�
The scan pauses until the signal
disappears�
The scan resumes immediately after the
signal disappears�
the signal disappears�
The scan remains paused for the
Pause Timer setting, even if the signal
disappears�
and DR scan�
The Temporary Skip channels are
skipped for the set period of time�
The Temporary Skip channels are
skipped until the scan is stopped�
The Temporary Skip channels are skipped
until the transceiver is turned OFF�
Rotating stops the scan�
transceiver version�
(Default: 10sec)
(Default: 2sec)
(Default: 5min)
(Default: Up/Down)