(F) Setting Of Acceleration/Deceleration Time And Acceleration/Deceleration Pattern - Mitsubishi Electric 800 Series Instruction Manual

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

5.5
(F) Setting of acceleration/deceleration time and
acceleration/deceleration pattern
Purpose
To set the motor acceleration/
deceleration time
To set the acceleration/
deceleration pattern suitable for an
application
To command smooth speed
transition with terminals
To set the starting frequency
5.5.1
Setting the acceleration and deceleration time
The following parameters are used to set motor acceleration/deceleration time.
Set a larger value for a slower acceleration/deceleration, and a smaller value for a faster acceleration/deceleration.
For the acceleration time at automatic restart after instantaneous power failure, refer to Pr.611 Acceleration time at a restart
(page
448).
Pr.
Name
20
Acceleration/deceleration
F000
reference frequency
21
Acceleration/deceleration
F001
time increments
16
Jog acceleration/
F002
deceleration time
611
Acceleration time at a
F003
restart
7
Acceleration time
F010
8
Deceleration time
F011
44
Second acceleration/
F020
deceleration time
45
Second deceleration time
F021
147
Acceleration/deceleration
F022
time switching frequency
791
Acceleration time in low-
F070
speed range
792
Deceleration time in low-
F071
speed range
815
Torque limit level 2
H710
1103
Deceleration time at
F040
emergency stop
190
5. PARAMETERS

5.5 (F) Setting of acceleration/deceleration time and acceleration/deceleration pattern

Acceleration/deceleration
time
Acceleration/deceleration
pattern and backlash
measures
Remote setting function
Starting frequency and
start-time hold
Initial value
Setting range
60 Hz
1 to 590 Hz
0
0
1
0.5 s
0 to 3600 s
9999
0 to 3600 s
9999
0 to 3600 s
*1
5 s
*2
15 s
0 to 3600 s
*1
10 s
*2
30 s
5 s
0 to 3600 s
9999
0 to 3600 s
9999
9999
0 to 590 Hz
9999
9999
0 to 3600 s
9999
9999
0 to 3600 s
9999
9999
0 to 400%
9999
5 s
0 to 3600 s
Parameter to set
P.F000 to P.F003, P.F010,
Pr.7, Pr.8, Pr.16, Pr.20,
P.F011, P.F020 to P.F022,
Pr.21, Pr.44, Pr.45,
P.F040, P.F070, P.F071,
Pr.147, Pr.611, Pr.791,
P.H710
Pr.792, Pr.815, Pr.1103
P.F100, P.F200 to P.F203
Pr.29, Pr.140 to Pr.143
P.F101
Pr.59
P.F102, P.F103
Pr.13, Pr.571
Description
Set the frequency that will be the basis of acceleration/
deceleration time. As acceleration/deceleration time, set the
frequency change time from a stop status to Pr.20.
Increment: 0.1 s
Select the increment for the
acceleration/deceleration time
Increment: 0.01 s
setting.
Set the acceleration/deceleration time for JOG operation (from
stop status to Pr.20).
Refer to
page
224.
Set the acceleration time for restart (from stop status to Pr.20).
Standard acceleration time (for example, Pr.7) is applied as the
acceleration time at restart. Refer to
Set the motor acceleration time (from stop status to Pr.20).
Set the motor deceleration time (from Pr.20 to stop status).
Set the acceleration/deceleration time when the RT signal is
ON.
Set the deceleration time when the RT signal is ON.
Acceleration time = deceleration time
Set the frequency where the acceleration/deceleration time
switches to the time set in Pr.44 and Pr.45.
No function
Set the acceleration time in a low-speed range (less than 10%
of the rated motor frequency).
The acceleration time set in Pr.7 is applied. (While RT signal is
ON, the second function is enabled.)
Set the deceleration time in a low-speed range (less than 10%
of the rated motor frequency).
The deceleration time set in Pr.8 is applied. (While RT signal is
ON, the second function is enabled.)
Set the torque limit level at a deceleration by turning ON the X92
signal.
The torque limit set to Pr.22 is valid.
Set the motor deceleration time at a deceleration by
turning ON the X92 signal.
Refer to
page
190
194
197
201,
202
page
448.

Advertisement