Setting
Signal
name
Positive
Negative
logic
logic
211
311
LUP
212
312
LDN
213
313
Y213
215
315
Y215
217
317
Y217
218
318
STIR
219
319
Y219
220
320
Y220
226
326
Y226
228
328
DRY
229
329
Y229
230
330
Y230
247
347
LSYN
248
348
Y248
249
349
Y249
250
350
Y250
9999
*1
Take caution when changing the frequency setting with an analog signal, because this change speed and the timing of the change speed
determined by the acceleration/deceleration time setting may cause the output of the SU (up to frequency) signal to switch repeatedly between
ON and OFF. (This repeating does not occur when the acceleration/deceleration time setting is "0 s".)
*2
The setting is available only for standard models.
*3
This signal cannot be assigned to the output terminals for plug-in options (FR-A8AY, FR-A8AR).
*4
Available when the plug-in option is connected.
*5
This signal is available when the PLC function is enabled, or when an option (FR-A8AY, FR-A8AR, FR-A8NC, or FR-A8NCE) is installed. For the
corresponding parameters of each option, refer to the Instruction Manual of the option.
*6
When the power is reset, the fault output 2 signal (ALM2) turns OFF at the same time as the power turns OFF.
NOTE
• The same function may be set to more than one terminal
• The terminal conducts during function operation when the setting is "0 to 99, 200 to 299", and does not conduct when the
setting is "100 to 199, 300 to 399".
• When Pr.76 Fault code output selection = "1", the output signals of terminals SU, IPF, OL and FU operate according to
Pr.76 setting. (When the inverter's protective function is activated, the signal output switches to fault code output.)
• The outputs of terminal RUN and the fault output relay are assigned according to the settings above, regardless of Pr.76.
• Changing the terminal assignment using Pr.190 to Pr.196 (Output terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
• Do not assign signals which repeat frequently between ON and OFF to terminals A1B1C1 or A2B2C2. The life of the relay
contacts will be shortened.
Function
Upper limit warning
Output when the load fault upper limit warning is
detection
detected.
Lower limit warning
Output when the load fault lower limit warning is
detection
detected.
During load characteristics
Output during measurement of the load
measurement
characteristics.
During cleaning
Output during operation of the cleaning
function.
Priming pump operation
Outputs the signal for starting the priming pump. Pr.1363
Stirring
Output during the stirring operation.
PID upper/lower limit pre-
Output when the PID measured value meets the
warning
requirements of the limit pre-warning signal
output conditions.
Second PID upper/lower
limit pre-warning
Auxiliary pressure pump
Output when the PID deviation exceeds the
operation
auxiliary pressure pump operation starting level.
Dry run
Output when a dry-run state is detected.
PID input pressure warning
Output when the pump inlet pressure reaches
the warning level.
PID input pressure fault
Output when the pump inlet pressure reaches
the fault level.
Phase synchronization
Output when phase synchronization for
*4
bypass switching has completed (for FR-
completion
A8AVP).
Estimated residual-life of
Output when the main circuit capacitor
main circuit capacitor (for
approaches the end of its estimated life.
*2*5
Pr.313 to Pr.322)
ABC1 relay contact life (for
Output when the relay contacts of terminals A1,
B1, and C1 approach the end of their life.
*5
Pr.313 to Pr.322)
ABC2 relay contact life (for
Output when the relay contacts of terminals A2,
*5
B2, and C2 approach the end of their life.
Pr.313 to Pr.322)
No function
Operation
Pr.1480 to
Pr.1492
Pr.1469 to
Pr.1479
Pr.1364, Pr.1365
Pr.1346, Pr.1370
to Pr.1373
Pr.1374, Pr.1375
Pr.42, Pr.43,
Pr.132, Pr.1144,
Pr.1370
Pr.1370,
Pr.1373,
Pr.1377,
Pr.1378, Pr.1380
Pr.1370,
Pr.1377,
Pr.1379, Pr.1381
Pr.139
Pr.255, Pr.506
Pr.255, Pr.507
Pr.255, Pr.508
5.8 (M) Monitor display and monitor output signal
Related
Refer
parameter
to
3
page
265
4
5
391
440
5
5
6
7
8
182
9
10
301
5. PARAMETERS