Mitsubishi Electric 800 Series Instruction Manual page 170

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Disabling parameter write (Pr.77 = "1")
• Parameter write, parameter clear and all parameter clear are disabled. (Parameter read is enabled.)
• The following parameters can be written even if Pr.77 = "1".
Pr.
22
Stall prevention operation level
75
Reset selection/disconnected PU detection/PU
stop selection
77
Parameter write selection
Operation mode selection
*1
79
160
User group read selection
296
Password lock level
*1
Writing during operation is disabled. To change the parameter setting value, stop the operation.
 Writing parameters during operation (Pr.77 = "2")
• These parameters can always be written.
• The following parameters cannot be written during operation if Pr.77 = "2". To change the parameter setting value, stop
the operation.
Pr.
23
Stall prevention operation level compensation
factor at double speed
48
Second stall prevention operation level
49
Second stall prevention operation frequency
60
Energy saving control selection
66
Stall prevention operation reduction starting
frequency
71
Applied motor
79
Operation mode selection
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
90 to 94
(Motor constant)
95
Online auto tuning selection
96
Auto tuning setting/status
135 to 139
(Electronic bypass sequence parameter)
178 to 196
(Input and output terminal function selection)
248
Self power management selection
254
Main circuit power OFF waiting time
261
Power failure stop selection
289
Inverter output terminal filter
291
Pulse train I/O selection
298
Frequency search gain
313 to 322
(Extended output terminal function selection)
329
Digital input unit selection
414
PLC function operation selection
415
Inverter operation lock mode setting
418
Extension output terminal filter
450
Second applied motor
453
Second motor capacity
Name
297
345, 346
496, 497
656 to 659
805
997
Name
454
455
456
457
458 to 462
463
507, 508
521
541
560
561
570
574
578
579
606
660 to 662
699
702
706, 707, 711,
712, 717, 721,
724, 725, 1412
738 to 746,
1413
800
858
859
860
868
998
999
1002
Pr.
Password lock/unlock
(DeviceNet communication)
(Remote output)
(Analog remote output)
Torque command value (RAM)
Fault initiation
Pr.
Number of second motor poles
Second motor excitation current
Rated second motor voltage
Rated second motor frequency
(Second motor constant)
Second motor auto tuning setting/status
(Display/reset ABC relay contact life)
Output short-circuit detection
Frequency command sign selection
Second frequency search gain
PTC thermistor protection level
Multiple rating setting
Second motor online auto tuning
Auxiliary motor operation selection
Motor connection function selection
Power failure stop external signal input selection
(Increased magnetic excitation deceleration)
Input terminal filter
Maximum motor frequency
(PM motor tuning)
(Second PM motor tuning)
Control method selection
Terminal 4 function assignment
Torque current/Rated PM motor current
Second motor torque current/Rated PM motor
current
Terminal 1 function assignment
PM parameter initialization
Automatic parameter setting
Lq tuning target current adjustment coefficient
5.4 (E) Environment setting parameters
Name
Name
169
5. PARAMETERS
3
4
5
5
5
6
7
8
9
10

Advertisement

Table of Contents