Mitsubishi Electric 800 Series Instruction Manual page 122

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Function
Pr.
Pr.
group
523
H320
*8
524
H321
*8
539
N002
USB
547
N040
548
N041
Communication 549
N000
550
D012
551
D013
552
H429
PID control
553
A603
554
A604
Current
555
E720
average value
556
E721
monitor
557
E722
560
A712
561
H020
563
M021
564
M031
565
G301
566
G302
Second motor
569
G942
constants
Multiple rating
570
E301
571
F103
573
A680
T052
574
C211
PID control
575
A621
576
A622
577
A623
Name
Emergency drive mode
100, 111, 112,
selection
121 to 124, 200, 211,
212, 221 to 224, 300,
311, 312, 321 to 324,
400, 411, 412,
421 to 424, 9999
Emergency drive
0 to 590 Hz, 9999
running speed
MODBUS RTU
0 to 999.8 s, 9999
communication check
time interval
USB communication
0 to 31
station number
USB communication
0 to 999.8 s, 9999
check time interval
Protocol selection
0, 1, 2
NET mode operation
0, 1, 9999
command source
selection
PU mode operation
1 to 3, 9999
command source
selection
Frequency jump range
0 to 30 Hz, 9999
PID deviation limit
0 to 100%, 9999
PID signal operation
0 to 7, 10 to 17
selection
Current average time
0.1 to 1 s
Data output mask time
0 to 20 s
Current average value
0 to 500 A
monitor signal output
reference current
0 to 3600 A
Second frequency
0 to 32767, 9999
search gain
PTC thermistor
0.5 to 30 k, 9999
protection level
Energization time
(0 to 65535)
carrying-over times
Operating time carrying-
(0 to 65535)
over times
Second motor excitation
0 to 400 Hz, 9999
current break point
Second motor excitation
0 to 300%, 9999
current low-speed
scaling factor
Second motor speed
0 to 200%, 9999
control gain
Multiple rating setting
0, 1
Holding time at a start
0 to 10 s, 9999
4 mA input check
1 to 4, 11 to 14, 21 to
selection
24, 9999
Second motor online
0, 1
auto tuning
Output interruption
0 to 3600 s, 9999
detection time
Output interruption
0 to 590 Hz
detection level
Output interruption
900 to 1100%
cancel level
Setting range
Minimum
setting
increments
1
0.01 Hz
0.1 s
1
0.1 s
1
1
1
0.01 Hz
0.1%
1
0.1 s
0.1 s
*2
*2
0.01 A
*3
*3
0.1 A
1
0.01 k
1
1
0.01 Hz
0.1%
0.1%
1
0.1 s
1
1
0.1 s
0.01 Hz
0.1%
Initial value
Refer
Customer
to
setting
page
9999
245
9999
245
9999
500
0
532
9999
532
0
478
9999
214
9999
214
9999
255
9999
396
0
396
1 s
187
0 s
187
Inverter rated
187
current
9999
353,
454
9999
230
0
274
0
274
9999
542
9999
542
9999
149
0
167
9999
201
9999
338
0
371
1 s
396
0 Hz
396
1000%
396
5. PARAMETERS
5.1 Parameter List
3
4
5
5
5
6
7
8
9
10
121

Advertisement

Table of Contents
loading

Table of Contents