Pr.
Register
918
42108
Terminal 1 gain (speed)
43918
Terminal 1 gain (speed) (terminal
analog value)
919
41919
Terminal 1 bias command (torque)
919
42109
Terminal 1 bias (torque)
43919
Terminal 1 bias (torque) (terminal
analog value)
920
41920
Terminal 1 gain command (torque)
920
42110
Terminal 1 gain (torque)
43920
Terminal 1 gain (torque) (terminal
analog value)
930
41930
Current output bias signal
930
42120
Current output bias current
931
41931
Current output gain signal
931
42121
Current output gain current
932
41932
Terminal 4 bias command (torque)
932
42122
Terminal 4 bias (torque)
43932
Terminal 4 bias (torque) (terminal
analog value)
933
41933
Terminal 4 gain command (torque)
933
42123
Terminal 4 gain (torque)
43933
Terminal 4 gain (torque) (terminal
analog value)
934
41934
PID display bias coefficient
934
42124
PID display bias analog value
43934
PID display bias analog value
(terminal analog value)
935
41935
PID display gain coefficient
935
42125
PID display gain analog value
43935
PID display gain analog value
(terminal analog value)
1000 to
45000 to
Refer to the parameter list
1999
45999
for parameter names.
• Fault history
Register
Definition
40501
Fault record 1
40502
Fault record 2
40503
Fault record 3
40504
Fault record 4
40505
Fault record 5
40506
Fault record 6
40507
Fault record 7
40508
Fault record 8
Parameter name
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
(page
108)
Read/write
Read/write
Read/write
Read
Read
Read
Read
Read
Read
Read
Remarks
Analog value (%) set to Pr.918
Analog value (%) of the voltage applied to the terminal 1
Analog value (%) set to Pr.919
Analog value (%) of the voltage applied to the terminal 1
Analog value (%) set to Pr.920
Analog value (%) of the voltage applied to the terminal 1
Analog value (%) set to Pr.930
Analog value (%) set to Pr.931
Analog value (%) set to Pr.932
Analog value (%) of the current (voltage) applied to the
terminal 4
Analog value (%) set to Pr.933
Analog value (%) of the current (voltage) applied to the
terminal 4
Analog value (%) set to Pr.934
Analog value (%) of the current (voltage) applied to the
terminal 4
Analog value (%) set to Pr.935
Analog value (%) of the current (voltage) applied to the
terminal 4
The parameter number + 44000 is the register number.
Remarks
Being 2 bytes in length, the data is stored as "H00".
Refer to the lowest 1 byte for the error code. (Refer to
for the error codes.)
Performing write using the register 40501 batch-clears the fault
history.
Set any value as data.
5.12 (N) Operation via communication and its settings
3
4
5
5
5
6
7
8
9
10
page 568
527
5. PARAMETERS