Mitsubishi Electric 800 Series Instruction Manual page 613

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

8
SPECIFICATIONS
This chapter explains the SPECIFICATIONS of this product.
Always read the instructions before using the equipment.
For the "SPECIFICATIONS" of the separated converter type, refer to the FR-F862 (Separated Converter Type) Instruction
Manual (Hardware).
8.1
Inverter rating
Model FR-F860-[ ]
Inverter capacity (kW)
Applicable
SLD
motor capacity
LD
*1
(kW)
Rated
SLD
capacity
LD
*2
(kVA)
Rated
SLD
*3
current (A)
LD
Overload
SLD
current
LD
*4
rating
*5
Rated voltage
Rated input
AC voltage/frequency
Permissible AC voltage
fluctuation
Permissible frequency
fluctuation
Rated input
Without
*6
DC
current (A)
reactor
With DC
reactor
Power
Without
supply
DC
capacity
reactor
*7
With DC
(kVA)
reactor
Protective structure (IEC 60529)
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the 4-pole standard motor.
*2
The rated output capacity indicated assumes that the output voltage is 575 V.
*3
When an operation is performed with the carrier frequency set to 3 kHz or more, and the inverter output current reaches the value indicated in
the parenthesis, the carries frequency is automatically lowered. The motor noise becomes louder accordingly.
*4
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty,
allow time for the inverter and motor to return to or below the temperatures under 100% load.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
However, the maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about
*6
The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor
and cables) affects the rated input current.
*7
The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of
the input reactor and cables).
612
8. SPECIFICATIONS
8.1 Inverter rating
00680
01080
45
75
45
75
45
75
68
108
62
99
68 (57.8)
108 (91.8)
62 (52.7)
99 (84.1)
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature 40°C
120% 60 s, 150% 3 s
(inverse-time
characteristics) at
surrounding air
temperature 40°C
Three-phase 525 to 600 V
Three-phase 525 to 600 V 60 Hz
472 to 660 V 60 Hz
±5%
SLD
87.0
LD
79.0
SLD
68.0
108.0
*3
(57.8)
(91.8)
LD
62.0
99.0
(52.7)
(84.1)
SLD
86.8
LD
79.1
SLD
68.0
108.0
LD
62.0
99.0
Open type (IP00)
Forced air
36
41
01440
01670
02430
90
110
132
110
110
185
90
110
150
144
167
242
131
152
221
144 (122)
167 (141)
243 (206)
131 (122)
152 (129)
221 (187)
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air
temperature 50°C
144.0
167.0
243.0
(122.0)
(141.0)
(206.0)
131.0
152.0
221.0
(122.0)
(129.0)
(187.0)
144.0
167.0
242.0
131.0
152.0
221.0
52
52
55
02890
03360
04420
160
220
250
220
260
335
185
220
300
288
335
441
254
303
401
289 (245)
336 (285)
442 (375)
255 (216)
304 (258)
402 (341)
289.0
336.0
442.0
(245.0)
(285.0)
(375.0)
255.0
304.0
402.0
(216.0)
(258.0)
(341.0)
288.0
335.0
441.0
254.0
303.0
401.0
112
115
153
.