Mitsubishi Electric 800 Series Instruction Manual page 124

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Function
Pr.
Pr.
group
608
H016
PID control
609
A624
610
A625
611
F003
617
G080
Speed
653
G410
smoothing
control
654
G411
Analog remote
655
M530
output function
656
M531
657
M532
658
M533
659
M534
Increased
660
G130
magnetic
excitation
deceleration
661
G131
662
G132
663
M060
665
G125
668
A786
675
A805
684
C000
Maintenance
686
E712
687
E713
688
E714
689
E715
Electronic
692
H011
thermal O/L
relay
693
H012
694
H013
695
H014
696
H015
699
T740
Name
Second motor
110 to 250%, 9999
permissible load level
PID set point/deviation
1 to 5
input selection
PID measured value
1 to 5, 101 to 105
input selection
Acceleration time at a
0 to 3600 s, 9999
restart
Reverse rotation
0 to 300%, 9999
excitation current low-
speed scaling factor
Speed smoothing
0 to 200%
control
Speed smoothing cutoff
0 to 120 Hz
frequency
Analog remote output
0, 1, 10, 11
selection
Analog remote output 1
800 to 1200%
Analog remote output 2
800 to 1200%
Analog remote output 3
800 to 1200%
Analog remote output 4
800 to 1200%
Increased magnetic
0, 1
excitation deceleration
operation selection
Magnetic excitation
0 to 40%, 9999
increase rate
Increased magnetic
0 to 300%
excitation current level
Control circuit
0 to 100°C
temperature signal
output level
Regeneration avoidance
0 to 200%
frequency gain
Power failure stop
0 to 200%
frequency gain
User parameter auto
1, 9999
storage function
selection
Tuning data unit
0, 1
switchover
Maintenance timer 2
0 (1 to 9998)
Maintenance timer 2
0 to 9998, 9999
warning output set time
Maintenance timer 3
0 (1 to 9998)
Maintenance timer 3
0 to 9998, 9999
warning output set time
Second free thermal
0 to 590 Hz, 9999
reduction frequency 1
Second free thermal
1 to 100%
reduction ratio 1
Second free thermal
0 to 590 Hz, 9999
reduction frequency 2
Second free thermal
1 to 100%
reduction ratio 2
Second free thermal
0 to 590 Hz, 9999
reduction frequency 3
Input terminal filter
5 to 50 ms, 9999
Setting range
Minimum
setting
increments
1%
1
1
0.1 s
0.1%
0.1%
0.01 Hz
1
0.1%
0.1%
0.1%
0.1%
1
0.1%
0.1%
1°C
0.1%
0.1%
1
1
1
1
1
1
0.01 Hz
1%
0.01 Hz
1%
0.01 Hz
1 ms
Initial value
Refer
Customer
to
setting
page
9999
230
2
396
3
396
9999
448,
454
9999
542
0%
564
20 Hz
564
0
312
1000%
312
1000%
312
1000%
312
1000%
312
0
562
9999
562
100%
562
0°C
316
100%
559
100%
458
9999
463
0
353,
363
0
186
9999
186
0
186
9999
186
9999
230
100%
230
9999
230
100%
230
9999
230
9999
343
5. PARAMETERS
5.1 Parameter List
3
4
5
5
5
6
7
8
9
10
123

Advertisement

Table of Contents
loading

Table of Contents