Description of the LDS
10.1.3

Menu overview

File
New
Open
Close
Close all
Save
Save as
Export
Load measurement pref-
erences
Save measurement pref-
erences
Protocol
Print
Print preview
Recently opened files
Exit
Edit
Copy
Clear plane
Clear all planes
Change user level
Measurement
Environment
Sensor parameters
FPM-Adjustment
Beamfind settings
CCD info
CCD settings
Power measurement
Single
Caustic
Start adjustment mode
Options
Revision 06 EN 02/2023
Opens a new file for the measuring data
Opens a measuring file with the extensions ".foc" or ".mdf"
Closes the file selected in the toolbar
Closes all files opened
Saves the current file in foc- or mdf format
Opens the menu for the storage of the files selected in the toolbar. Only files with the
extensions ".foc" or ".mdf" can be imported safely
Exports all current data in protocol format ".xls" and ".pkl"
Opens a file with measurement settings with the extension ".ptx"
Opens the menu to save the settings of the last program run. Only files with the extension
".ptx" can be opened
Starts a protocol of the numeric results. They can either be written into a file or a data base
Opens the standard print menu
Shows the content of the printing order
Shows the file opened before
Terminates the program
Copies the current window to the clipboard
Deletes the data of the plane selected in the toolbar
Deletes all data of the file selected in the toolbar
By entering a password a different user level can be activated.
Different system parameters can be entered, e.g.
- Reference value for the laser power
- Focal length (Not relevant for FPM)
- Wavelength
- Comment
- Device offset (distance FPM - beam source)
The following device parameters can be e.g. set here:
- The spatial resolution (32, 64, 128 or 256 Pixel)
- The manual settings of the z-axis
- Choosing the measuring devices connected to the bus
- Deactivating the z-axis
Adjustment of the incident laser beam
Setting parameter for a beamfind procedure
Provides information on device parameters
Special settings can be made, e.g.:
- Trigger mode
- Trigger level
- Exposure time
- Wave length
Not relevant for FPM
This menu item enables the start of single measurements, of the monitor mode and the
video mode
Enables the start of a caustic measurement. Not only automatic measurements but also
serial measurements of manually set parameters are possible.
The automatic measurement starts with a beam search and then caries out the entire
measuring procedure independently. Only the z-range that is to be examined as well as
the desired measuring plane have to entered
Not relevant for FPM
Enables the setting of device parameters
45