The correct integration and implementation of the measurement process is required (e.g. the handshake
to trigger a measurement). The individual measurement sequences are described in detail in chapter „12.1
Measuring procedure" on page 61 and then shown in timing diagrams.
Required control parameters (OUT):
Adress
Parameter
272
Exposure time
Required result parameters (IN):
Adress
Parameter
326
% Override
342
Exposure time used
346
Optimal exposure time
282.5
Irradiation failure
292
WarnSingle
The internal evaluation uses the results of a measurement to calculate the ideal exposure time. For this
approximately 3300-3500 cts are achieved in the measurement in order to balance out minimal fluctuations
in output.
When the exposure time is close to the optimum, i.e. there is only slight over - or underexposure, this calculation
provides reliable values.
If the exposure time is too long, several iterative steps are necessary in order to reach the optimal range.
If the exposure time is too short, there may not be enough of a signal to facilitate an evaluation. The resulting
values will then be unrealistic and the optimal setting for the exposure time incalculable.
It is therefore better to start with overly long exposure times and several steps until the optimum setting has
been determined.
56
Value
Comment
0
0
No setup use
0
0
FALSE
Normal measurement with measurement result transfer
FALSE
FALSE
valuation with 2nd moments
FALSE
TRUE
Exposure is controlled via exposure time
FALSE
Deactivated, because single pulse measurement
TRUE
Mode for single pulse measurement
FALSE
Use of integrated pulse detection
FALSE
Disable cw measurement
TRUE
FALSE
Handshake signals for saving a setup
FALSE
Value
Comment
20000
[µs]; 20ms as initial value
Comment
percentage area of the measured beam is overridden
[µs]; value as specified in the output
optimal exposure time calculated from the measurement
general warning during measurement
warning code for the last measurement
FocusParameterMonitor FPM
Revision 06 EN 02/2023