Connections
7.2

FPM PROFINET

Fig. 7.4:
Connections FPM PROFINET
7.2.1

Interface description PROFINET

Both the bus interface and the power supply are duplicated so that the FPM can be inserted into a line structure.
There are five interfaces in total:
2 x PROFINET
ports
®
2 x 24 V power supplies (24 V ± 5 %, max. 500 mA)
1 x Ethernet port
The data are stored in registers in Motorola format. This means that high bytes are stored first and the lower
bytes follow on the next registers.
PROFINET
(Port 1/Port 2):
®
The PROFINET
connectors are AIDA-compatible RJ45 connectors. The two RJ45 sockets are internally
®
connected via an integrated switch.
Power supply (Power):
Power is supplied via AIDA-compatible connectors. The two connectors are internally connected 1:1.
The FPM has a current requirement that is less than 500 mA, drawn from the sensor supply.
Pin assignment (top view mating side)
5
1
Tab. 7.3:
Connector power supply
Revision 06 EN 02/2023
®
PROFINET
®
-Ports
Maintenance
hatch with
Ethernet port
®
®
Pin
1
2
3
4
5
Voltage supply
Function
Sensor power supply 24 V
GND sensor
Actuator power supply 24 V
GND actuator
FE (functional earth)
23