Presentation
False colors
False colors (filtered)
Isometry
Isometry 3D
Review (86%)
Review (2. Moments)
Caustic
Raw beam
Symmetry check
Fixed contour lines
Variable contour lines
Graphical review
System state
Evaluation parameter
Color tables
Toolbar
Position
Evaluation
Communication
Rescan bus
Free Communication
Scan device list
Script
Editor
List
Python
Help
Activation
About LDS
Tab. 10.1:
Menu overview
46
False color display of the spatial power density distribution
Usage of a spatial filtration (spline function) on the false color display of the power density
distribution
3-dimensional display of the spatial power density distribution
Allows a 3D display of caustic and power density distribution with spatial rotation as well
as an optional isophote display
Numerical overview of measuring results in the different layers basing on the 86% beam
radius definition
Numerical overview of the measuring results in the different layers basing on the 2
beam radius definition
Results of the caustic measurement and the results of the caustic fit – such as beam
quality factor M², focus position and focus radius
Information about the raw beam back calculation
Analysis tool to check the beam symmetry especially for the alignment of laser resonators.
No standard feature of the device
Display of the spatial laser density distribution with fixed intersection lines for 6 different
power levels
Display of the spatial power density distribution with freely selectable intersection lines
Enables a selection of graphical displays – among them the radius, the x- and y- position
above the z-position and the time
Not relevant for FPM
Loading stored evaluation parameters
Different color charts are available in order to analyse e.g. diffraction phenomena in detail
In order to display or to hide the toolbar
Moving the device into a defined position
Comparison of the measured values with defined limit values and evaluation (optionally)
The system searches the bus for the different device addresses. This is necessary whenever
the device configuration at the PRIMES bus was changed after starting the software.
Display of the communication on the PRIMES bus
Lists the device addresses of the single PRIMES devices
Opens the script generator, a tool, by means of which complex measuring procedures
are controlled automatically (with a script language developed by PRIMES).
Shows a list of the opened windows
Opens the script generator in order to control complex measuring procedures automatically
(scripting language Python)
Enables the activation of special functions
Provides information regarding the software version