D. Startup by I/O Input
This section describes the speed control mode operation by I/O input.
• Servo ON by I/O input
The Servo-ON status is made when inputting ON signal in SERVO ON/OFF input
-----
terminal
SV-ON (CN1 pin number 3).
Input +24V
Servo ON Signal
Operator displays the following when the servo is ON from speed control mode.
• Speed Control Mode
Setting of the speed control mode:
Setting value of SEt-41 = 1
Chapter 3. Startup and Adjustment 3 - 11
+24VIN
SV-ON
+24V
Fig 3.6 Servo ON
GND
SERVO DRIVE
CN1 Pin 1
CN1 Pin 3
(Different according to the control mode.)