Fig 8.2 Connection Diagram Of Alarm Related Output Signal - OE Max Controls CSDJ Plus User Manual

Hide thumbs Also See for CSDJ Plus:
Table of Contents

Advertisement

8 - 4 CSDJ Plus Servo Drive User's Manual
8.2 Alarm Output Signal
CSDJ Plus Servo Drive has output terminal SALM, AL1, AL2, AL3, which indicates the alarm
occurrence to the external.
Maximum Voltage: 30V
Maximum Current: 50mA
Maximum Voltage Used : 30V
Maximum Current Used : 20mA
External Power
24V
R
Alarm Reset Input

Fig 8.2 Connection Diagram of Alarm Related Output Signal

Table 8.1 Alarm Related Input/Output Terminal
Name
Pin No.
SALM+
CN1 pin 45
SALM-
CN1 pin 46
AL1
CN1 pin 37
AL2
CN1 pin 38
AL3
CN1 pin 39
ALM-SG
CN1 pin 40
--------
CN1 pin 7
ALM-RST
SERVO DRIVE
CN1 Pin 45
CN1 Pin 46
CN1 Pin 37
CN1 Pin 38
CN1 Pin 39
CN1 Pin 40
CN1 Pin 1
ALM-RST
CN1 Pin 7
ON when error occurs.
(If the external power is 24V, pin 45-46 is 24V)
0V
Alarm code occurrence output.
(Normally each terminal always maintains low level.)
0V
Alarm Reset Input.
- When alarm occurs, eliminate the cause and turn ON the input signal
to reset the alarm.
- Reset the alarm only when terminal is Open → Closed.
(Operate not in LEVEL but EDGE.)
External Power
24V
SALM+
SALM-
0V
AL1
AL2
AL3
ALM-SG
0V
HOST CONTROLLER
Description
--------
ALM-RST

Advertisement

Table of Contents
loading

Table of Contents