Fig 6.10 Zero-Clamp Operation - OE Max Controls CSDJ Plus User Manual

Hide thumbs Also See for CSDJ Plus:
Table of Contents

Advertisement

Zero-Clamp Level
---------
P-CON Input Terminal
Zero-Clamp Level
E. Auto Zero-Clamp Speed Control Mode
This is a control mode, which always operates zero-clamp function.
Other operations are same as manual zero-clamp speed control mode.
Table 6.7 Auto Zero-Clamp Speed Control Mode Setting
SEt-41
SEt-17
V-ref (CN1 pin 19,20)
----------
P-CON (CN1 pin 6)
ON: The corresponding input terminal is connected to input voltage GND(0V)
OFF: The corresponding input terminal is connected to +24VIN or it is not connected
Speed Command
Zero-Clamp OFF
Motor
Speed

Fig 6.10 Zero-Clamp Operation

Setting
5
1∼5000[RPM]
-10∼10V
ON
OFF
Chapter 6. Basic Functions 6 - 13
Zero-Clamp ON
Description
Auto zero-clamp speed control mode
Zero-Clamp Operation Level
Speed command
P control
PI control
Time
Time