Fig 3.3 Setting The Jog Operation Speed - OE Max Controls CSDJ Plus User Manual

Hide thumbs Also See for CSDJ Plus:
Table of Contents

Advertisement

3 - 8 CSDJ Plus Servo Drive User's Manual
C. Startup by the Operator
Setting the Jog Operation Speed
Setting the Acceleration and Deceleration Time
Servo ON and Startup by the Operator
• Setting the Jog Operation Speed
ENTER
Power ON
MODE
SET
4 times
2 times
ENTER
MODE
The key must be pressed to save the changed value.
SET

Fig 3.3 Setting the Jog Operation Speed

Set in RPM from user parameter SEt-25.
Acceleration time : User parameter SEt-19
Deceleration time : User parameter SEt-20
Jog operation can be done from
Usr-01 of user mode.
Display differs according to
the set control mode.
Jog operation speed
Factory setting
Set the speed using
the keys.