ValvePositionControl_DemandValueGenerator_Ramp
Index
Subindex
Name
0x6332
1
AccelerationTimePositive
0x6332
2
Unit
0x6332
3
AccelerationTimePositive_Prefix
0x6333
1
AccelerationTimeNegative
0x6333
2
Unit
0x6333
3
AccelerationTimeNegative_Prefix
0x6335
1
DecelerationTimePositive
0x6335
2
Unit
0x6335
3
DecelerationTimePositive_Prefix
0x6336
1
DecelerationTimeNegative
0x6336
2
Unit
0x6336
3
DecelerationTimeNegative_Prefix
Chapter "1.6.2 Definition of unit and prefix", page 5
<AccelerationTimePositive>
This parameter defines the output signal's maximum rate of change on the positive side. The acceleration
time corresponds to the time that the signal needs for a change of 0 to 100 %.
The acceleration time can be specified in seconds with the gradation 1 s, 100 ms, 10 ms, 1 ms.
<DecelerationTimePositive>
This parameter defines the output signal's maximum rate of change on the positive side. The deceleration
time corresponds to the time that the signal needs for a change of 100 to 0 %.
The deceleration time can be specified in seconds with the gradation 1 s, 100 ms, 10 ms, 1 ms.
<AccelerationTimeNegative>
This parameter defines the output signal's maximum rate of change on the negative side. The acceleration
time corresponds to the time that the signal needs for a change of 0 to 100 %.
The acceleration time can be specified in seconds with the gradation 1 s, 100 ms, 10 ms, 1 ms.
<DecelerationTimeNegative>
This parameter defines the output signal's maximum rate of change on the negative side. The deceleration
time corresponds to the time that the signal needs for a change of 100 to 0 %.
The deceleration time can be specified in seconds with the gradation 1 s, 100 ms, 10 ms, 1 ms.
© Moog GmbH
USER MANUAL Firmware RKP-D (B99224-DV007-CE400; Version 1.1, 09/08)
Persis-
Data type
Access
tence
UINT16
rw
Y
UINT8
ro
N
INT8
rw
Y
UINT16
rw
Y
UINT8
ro
N
INT8
rw
Y
UINT16
rw
Y
UINT8
ro
N
INT8
rw
Y
UINT16
rw
Y
UINT8
ro
N
INT8
rw
Y
Demand Value Generator
Value
range
Default
UINT16
0
UINT8
3
-4...0
-3
UINT16
0
UINT8
3
-4...0
-3
UINT16
0
UINT8
3
-4...0
-3
UINT16
0
UINT8
3
-4...0
-3