7 Pump functions

7.1.2.4 Scaling

This function is used to scale the position setpoint, i.e., to influence the input signal's value range. The output
signal is derived from an offset and the multiplication of the input signal with a factor (sets the signal's slope)
according to the following function:
ValvePositionControl_DemandValueGenerator_Scaling
Index
Subindex
Name
0x6322
0
Factor
0x6323
1
Offset
0x6323
2
Unit
0x6323
3
Prefix
Chapter "1.6.2 Definition of unit and prefix", page 5
<Factor>
Factor by which the input is multiplied. It is calculated from a numerator (upper 16 bits of the parameter) and a
denominator (lower 16 bits of the parameter).
Bit
Meaning
The default value 0x00010001 corresponds to the factor 1.
<Offset>
The offset is added to the scaled input value.
© Moog GmbH
(
output
=
input
Factor
=
output
<Offset> (0x6323)

Figure 17: Scaling function

Data type
UINT32
INT16
UINT8
INT8
31
Numerator

Table 44: Data structure of the scaling factor

USER MANUAL Firmware RKP-D (B99224-DV007-CE400; Version 1.1, 09/08)
×
)
Factor
+
Offset
numerator
----------------------------------- -
denominator
slope = <Factor> (0x6322)
input
Persis-
Access
tence
rw
Y
rw
Y
ro
N
ro
N
16 15
Denominator
Demand Value Generator
Value range
Default
UINT32
0x00010001
INT16
0
UINT8
0
INT8
0
0
58