Technical Data Actuator Controls - AUMA SAEx 07.2-UW Operation Instructions Manual

Multi-turn actuators
Table of Contents

Advertisement

SAEx 07.2-UW
Technical data
Electronic control unit
Non-Intrusive setting
Position feedback signal
Torque feedback signal
Running indication
Heater in switch compartment
Service conditions
Use
Enclosure protection according to
EN 60529
Mounting position
Installation altitude
Ambient temperature
Humidity
Pollution degree according to IEC
60664-1
Vibration resistance according to
IEC 60068-2-6
Corrosion protection
Coating
Colour
Lifetime
Sound pressure level
Further information
EU Directives
13.2.

Technical data Actuator controls

Features and functions
Explosion protection
External supply of the electronics
(option)
Overvoltage category
Rated power
78
SAEx 16.2-UW / SAREx 07.2-UW
Magnetic limit and torque transmitter (MWG)
Turns per stroke: 1 to 500 (standard) or 10 to 5,000 (option)
Via actuator controls
Via actuator controls
Blinking signal via actuator controls
Resistance type heater with 5 W, 24 V AC
For continuous underwater use as well as indoor and outdoor use.
Increased enclosure protection IP68-C8. The maximum permissible head of water is 8 m.
Any position
≤ 2,000 m above sea level
> 2,000 m above sea level on request
-30 °C to +40 °C/+60 °C
Up to 100 % relative humidity across the entire permissible temperature range
Pollution degree 4 (when closed), pollution degree 2 (internal)
2 g, from 10 to 200 Hz
Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be
derived from this. Not valid in combination with gearboxes.
KX-G: Suitable for use in freshwater (lm1), seawater (lm2) and on seafloor (lm3), aluminium-free version
(outer parts)
Double layer powder coating
Standard:
AUMA silver-grey (similar to RAL 7037)
Option:
Available colours on request
AUMA multi-turn actuators meet or exceed the lifetime requirements of EN 15714-2. Detailed information
can be provided on request.
< 72 dB (A)
ATEX Directive 2014/34/EU
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
RED Directive 2014/53/EU
Refer to name plate
24 V DC: +20 %/ 15 %,
Current consumption: Basic version approx. 250 mA, with options up to 500 mA
For external electronics supply, the power supply of integral controls must have an enhanced isolation
against mains voltage in compliance with IEC 61010-1 and the output power be limited to 150 VA.
Category III according to IEC 60364-4-443
The actuator controls are designed for the nominal motor power, refer to motor name plate
SAREx 16.2-UW Control unit: electronic (MWG)
ACExC 01.2 Non-Intrusive Profibus DP