SAEx 07.2-UW
SAEx 16.2-UW / SAREx 07.2-UW
ACExC 01.2 Non-Intrusive Profibus DP
5.3.2.
Handwheel permanently mounted
5.3.2.1. Handwheel fitting
Handwheel fitting
for emergency operation and setting tasks
Figure 14: Version with permanently mounted handwheel (with bellows)
For actuator in version with permanently mounted handwheel, the handwheel is
provided for operation during setting tasks and for emergency operation of the
actuator. The handwheel is also approved for continuous immersion. Handwheel
activation is protected by specific bellows against deposits.
Figure 15: Handwheel fitting
[1]
Spacer
[2]
Input shaft
[3]
Handwheel
[4]
Retaining ring
[5]
Schlauchschelle
[6]
Bellows
Information: For transport reason, handwheels with a diameter of 400 mm and
larger are supplied separately within the scope of delivery. Handwheel ≦ 315
mm are already mounted.
1.
If required, fit spacer [1] on input shaft [2].
2.
Slip handwheel [3] onto input shaft.
3.
Secure handwheel [3] using the retaining ring [4] supplied.
4.
Put bellows [6] over push button and secure with hose clamp [5].
SAREx 16.2-UW Control unit: electronic (MWG)
Assembly
19