Transport And Storage; Transport - AUMA SAEx 07.2-UW Operation Instructions Manual

Multi-turn actuators
Table of Contents

Advertisement

SAEx 07.2-UW

Transport and storage

4.
Transport and storage
4.1.

Transport

Weights
14
SAEx 16.2-UW / SAREx 07.2-UW
For transport to place of installation, use sturdy packaging.
Suspended load!
Death or serious injury.
Do NOT stand below suspended load.
Attach ropes or hooks for the purpose of lifting by hoist only to housing and NOT
to handwheel.
Actuators mounted on valves: Attach ropes or hooks for the purpose of lifting
by hoist to valve and NOT to actuator.
Actuators mounted to gearboxes: Attach ropes or hooks for the purpose of lifting
by hoist only to the gearbox using eyebolts and NOT to the actuator.
Respect total weight of combination (actuator, gearbox, valve)
Secure load against falling down, sliding or tilting.
Perform lift trial at low height to eliminate any potential danger e.g. by tilting.
Figure 9: Example: Lifting the actuator
Table 6:
Weights of multi-turn actuators SAEx 07.2-UW
UW
with 3-phase AC motors
Type designation
Actuator
SAEx 07.2-UW/
SAREx 07.2-UW
SAEx 07.6-UW/
SAREx 07.6-UW
SAEx 10.2-UW/
SAREx 10.2-UW
SAEx 14.2-UW/
SAREx 14.2-UW
SAREx 16.2-UW Control unit: electronic (MWG)
ACExC 01.2 Non-Intrusive Profibus DP
SAEx 16.2-UW / SAREx 07.2-UW
1)
Motor type
VDX...
ADX...
VDX...
ADX...
VDX...
ADX...
VDX...
ADX...
SAREx 16.2-
2)
Weight
approx. [kg]
25
26
25
27
31
33
54
58

Advertisement

Table of Contents
loading

Table of Contents