Storage - AUMA SAEx 07.2-UW Operation Instructions Manual

Multi-turn actuators
Table of Contents

Advertisement

SAEx 07.2-UW
SAEx 16.2-UW / SAREx 07.2-UW
ACExC 01.2 Non-Intrusive Profibus DP
4.2.

Storage

Long-term storage
Weights of multi-turn actuators SAEx 07.2-UW
UW
with 3-phase AC motors
Type designation
Actuator
SAEx 14.6-UW/
SAREx 14.6-UW
SAEx 16.2-UW/
SAREx 16.2-UW
1)
Refer to motor name plate
2)
Indicated weight includes AUMA NORM multi-turn actuator with 3-phase AC motor, electrical con-
nection or plug/socket connector incl. cable glands (approx. 2.3 kg) as well as output drive type B1.
For other output drive types, heed additional weights. Heed weight of cables if plug/socket connector
is linked.
Risk of corrosion due to inappropriate storage!
Store in a well-ventilated, dry room.
Protect against floor dampness by storage on a shelf or on a wooden pallet.
Cover to protect against dust and dirt.
Apply suitable corrosion protection agent to uncoated surfaces.
Risk of damage due to excessively low temperatures!
Actuator controls may only be stored permanently down to 30 °C.
On request, actuators controls may be transported in specific cases and for
short duration at temperatures down to 60 °C.
For long-term storage (more than 6 months), observe the following points:
1.
Prior to storage:
Protect uncoated surfaces, in particular the output drive parts and mounting
surface, with long-term corrosion protection agent.
2.
At an interval of approx. 6 months:
Check for corrosion. If first signs of corrosion show, apply new corrosion protec-
tion.
SAREx 16.2-UW Control unit: electronic (MWG)
SAEx 16.2-UW / SAREx 07.2-UW
1)
Motor type
VDX...
ADX...
VDX...
ADX...
Transport and storage
SAREx 16.2-
2)
Weight
approx. [kg]
56
62
72
93
15

Advertisement

Table of Contents