Technical Data Actuator Controls - AUMA SQVEx 05.2 Manual

Part-turn actuators
Hide thumbs Also See for SQVEx 05.2:
Table of Contents

Advertisement

SQVEx 05.2
Technical data
Service conditions
Colour
Lifetime
Sound pressure level
Other
EU Directives
Reference documents
14.2.

Technical data Actuator controls

Features and functions
Explosion protection
Certificates and standards
Particular conditions of use
Power supply
External supply of the electronics
(option)
Rated power
Control and feedback signals
90
SQVEx 14.2/ SQRVEx 05.2
Standard:
AUMA silver-grey (similar to RAL 7037)
Option:
Other colours on request
AUMA part-turn actuators meet or exceed the lifetime requirements of EN ISO 22153. Detailed inform-
ation can be provided on request.
< 72 dB (A)
ATEX Directive 2014/34/EU
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
RED Directive 2014/53/EU
Dimensions Part-turn actuators SQVEx 05.2 SQVEx 14.2/SQRVEx 05.2 SQRVEx 14.2 with ACVExC
01.2
Electrical data Part-turn actuators SQVEx 05.2
Electrical data Part-turn actuators SQRVEx 05.2
Refer to name plate
Certificates are attached to the device. All standards applied and their respective issues are indicated
on these certificates.
The particular conditions of use are listed on the certificates supplied.
Standard voltages AC:
3-phase AC
Voltages/frequencies
Volt
220
240
Hz
50
60
Permissible variation of mains frequency: ± 5 %
Permissible variation of mains voltage: ± 10 %
30 % for maximum 10 seconds within a range of 380 V
If required, the motor speed will be reduced down to nominal speed depending on the load of the
actuators used
A low mains voltage increases the mains current consumption; a higher mains voltage reduces the
mains current consumption
The torque limits of the actuators used might be decreased for a short time, if applicable
24 V DC: +20 % / 15 %
Current consumption: Basic version approx. 250 mA, with options up to 500 mA
For external electronics supply, the power supply of integral controls must have an enhanced isolation
against mains voltage in compliance with IEC 61010-1 and the output power be limited to 150 VA.
The actuator controls are designed for the rated power motor power, refer to motor name plate
Via Modbus RTU interface
SQRVEx 14.2 Control unit: electronic (MWG)
SQVEx 14.2
SQRVEx 14.2
1-phase AC
Voltages/frequencies
380
480
Volt
50
60
Hz
480 V with the following restrictions:
ACVExC 01.2 Modbus RTU
110
120
220
240
50
60
50
60

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sqvex 14.2Sqrvex 05.2Sqrvex 14.2Sqve series

Table of Contents