SAEx 07.2-UW
Technical data
Features and functions
Motor protection evaluation
Overvoltage protection (option)
Threads for cable entries
Wiring diagram
Further options for version with MWG in actuator
Setting of limit and torque switching via local controls
Torque feedback signal
Wiring diagram
Service conditions
Use
Mounting position
Installation altitude
Ambient temperature
Humidity
Enclosure protection in accordance
with IEC 60529
Pollution degree according to
IEC 60664-1
Vibration resistance according to
IEC 60068-2-6
Corrosion protection
Coating
Colour
Accessories
Wall bracket
Programming software
Further information
Weight
EU Directives
80
SAEx 16.2-UW / SAREx 07.2-UW
Standard:
PTC tripping device in combination with PTC thermistors within actuator motor
Option:
Thermal overload relay in controls combined with thermoswitches within actuator
Protection of the actuator and control electronics against overvoltages on the fieldbus cables of up to 4
kV
Standard:
Metric threads
Options:
Pg-threads, NPT-threads, G-threads
Refer to name plate
Via fieldbus interface
Refer to name plate
Indoor and outdoor use permissible
Any position
≤ 2 000 m above sea level
> 2,000 m above sea level, on request
Refer to name plate of actuator controls
Up to 100 % relative humidity across the entire permissible temperature range
IP68
According to AUMA definition, enclosure protection IP68 meets the following requirements:
Depth of water: Maximum 8 m head of water
Continuous immersion in water: maximal 96 hours
For exact version, refer to actuator controls name plate.
Pollution degree 4 (when closed), pollution degree 2 (internal)
1 g, from 10 Hz to 200 Hz
Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be
derived from this. (Not valid in combination with gearboxes)
Standard:
KS
Suitable for use in areas with high salinity, almost permanent condensation, and
high pollution.
Option:
KX
Suitable for use in areas with extremely high salinity, permanent condensation,
and high pollution.
Double layer powder coating
Two-component iron-mica combination
Standard:
AUMA silver-grey (similar to RAL 7037)
Option:
Available colours on request
For fixing actuator controls mounted separately from the actuator, including plug/socket connector,
connecting cable on request
Cable length between actuator and actuator controls is max. 100 m.
AUMA CDT (Commissioning and Diagnostic Tool for Windows-based PC)
AUMA Assistant App (Commissioning and Diagnostic Tool)
Approx. 12 kg (with AUMA KT Ex plug/socket connector)
ATEX Directive 2014/34/EU
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU