PSA Arm Adjustment

Page 36
1. Open door and lock down #1 screw (pivoting set screw) of
PSA arm, and loosen setscrews #3 and #4.
2. Adjust #2 screw (PSA vertical adjustment screw) on PSA
arm to lift the door and ball catch lead edge into alignment
with ball catch receiver. (Note, if the glass has not
previously been installed, you will need to recheck
alignment once the glass is in place and readjust as
necessary.)
3. Once the adjustment is complete, tighten remaining
setscrews #3 and #4 on PSA arm and close the door
engaging the ball catch.
4. Confirm that the lead edge of the door and lead edge of the
carriers are still flush.
Issued: 9-22-2011
US23-2101-02 Rev A