Assa Abloy Besam VersaMax ICU Installation Manual page 19

Telescopic equal panel
Table of Contents

Advertisement


US23-2101-02 Rev A
3. Using the measurements provided, lay the track in place,
mark the holes, then remove track and drill for anchors.
Note!
The G track is not to be mounted and leveled any lower than the
bottom of the jamb and it must have an equal measurement from
the top of the G track to the bottom of the header across its
entire length.
4. Secure the track to the floor with concrete anchors and
#12x2" long countersunk screws supplied with door
package, leveling it with shims from end-to-end. (If possible,
a sealant should be used under the track assembly.)
5. After securing the track, check the track again to ensure
that it is still level. Measure from the top of the track to the
bottom of the header, checking for the same result at each
fastener.
Note!
All screws must be countersunk and fully tightened to avoid
interference with guide system travel.
Issued: 9-22-2011
RECESSED TRACK
(PIN GUIDE)
Page 19