The flush bolt assembly is factory installed and adjusted and
should not require adjustment.
Operation and function of the bolt should be checked at
installation.

Pre-Installation Check

1. Check operation by moving the level between the "LOCK" to
the "UNLOCK" positions several times. (The lever should
move freely without binding.)
2. Move the lever to the "UNLOCK" position, check the location
of the pin(s) in relation to the door stile. The pin(s) should not
extend beyond the end of the door stile.
3. Move the lever to the "LOCK" position, measure the
extension of the pin(s) beyond the door stile. (The pin(s)
should extend from 3/8" to 1/2" beyond the door stile.)
Note!
On door(s) equipped with Positive Latch, the bottom pin should
align and engage the hole in the Swing Arm.

Post-Installation Check

Note!
Check function of Flush Bolt after adjusting door heights and
alignment.
Positive Latch and "C" Handle Options
1. With lever in the "LOCK" position, open the door
approximately half way.
2. Push the bottom of the active leaf away / apart from the
sidelite. (Proper bolt function will lock the Swing Arm closed
and the doors should not separate.)
3. Open the door fully.
4. With lever in the "LOCK" position, attempt to cause the door
to breakout. (If the bolt is functioning properly, it will be
engaged in the header and the door will not break out.)
5. With the door, fully open, move the lever to the "UNLOCK"
position and break-out the doors. (The Swing Arm should
open and allow the doors to separate as they swing out and
the handle should not contact the sidelite.)
Flush Bolt Only Option
Open the door fully and with the lever in the "LOCK" position,
attempt to cause the door to breakout. (If the bolt is functioning
properly, it will be engaged in the header and the door will not
break out.)