Download Print this page
Assa Abloy ABLOY DA401 Manual
Assa Abloy ABLOY DA401 Manual

Assa Abloy ABLOY DA401 Manual

Swing door operator

Advertisement

Quick Links

ABLOY@DA401 / DA402
- Swing
door operator
--_
..
PROGRAM VERSION 1.53
AbloyOy
An ABBA ABlOY
Group company

Advertisement

loading

Summary of Contents for Assa Abloy ABLOY DA401

  • Page 1 ABLOY@DA401 / DA402 - Swing door operator PROGRAM VERSION 1.53 AbloyOy An ABBA ABlOY Group company...
  • Page 2 SPRING AND DOOR OPEN POSITION PULSE DISK A pulse disk fitted to the drive shaft is used to detennine the door closed position. This is achieved by the pulse counter calculating a series of holes around the circumference of the disk, one of which is open. When the perimeter sensor locates the edge of the notch the door operator stops the door.
  • Page 3: Signal Led's

    DISPLAY CONTROL UNIT ADJUSTMENTS AND SELECTIONS Control unit: When the mains supply is connected, the control unit immediately adopts the status determined by the program selector and the opening pulses. Only the green OK LED is lit. Press one of the three buttons and the display will show the status of the door operator.
  • Page 4 DISPLAY ~818 Safety sensor active. - Door stops opening and continues after the obstade has removed. - If safety sensor is OK, check the 1000 ohm resistor in connectors 4 and 5. ~8I8J Locking circuit active Le. the bolt in the lock case is out. •...
  • Page 5 BUTTONS Buttons: a) 5 button 800J' This button is used to call control points 0...28 onto '-I. the display. With the light on the digital display, press the S button for at least 3 seconds enabling yellow Adjustment LED to light. Digit 1 with a signal dot appears on the right.hand side digital display to indicating the first control point.
  • Page 6 SPRING AND DOOR OPEN POSITION SPRING TENSION AND DOOR OPEN POSITION 1. Make sure that program switch is on position MANUAL and power is OFF. 2. Check that the opening in the pulse disk is inside the pulse counter. - DO NOT MOUNT THE ARM YET. 3.
  • Page 7 SPRING AND DOOR OPEN POSITION 8. The RED LED flashes 4 times per second, when tension is near the selected class. - When the door closer shaft stops rotating (takes about .80s) mount the ann (Door must be in dosed position). 9.
  • Page 8: Control Points

    CONTROL POINTS Control points are presented in numerical order 0...28. Study all the control pointsto ensure the optimum possible operation of the door. Adjust the functions ensuringthe safety clutch does not slip. Factory Control Control selting Description point value Opening direction: Starting point of final speed 3 ...60 Door open position 3 ...60...
  • Page 9 CONTROL POINTS OOORUMITS Opening direction: Starting point of final spee The opening angle, where the operator changes from initial speed to final speed. (1 digit approx. 2°) Ensure adequate angle for final speed! 3...60 Door open position Max. open angle 100°. Ensure adequate angle for final speed! (1 digit approx.
  • Page 10 CONTROL POINTS DOOR SPEEDS Opening speed Adjust the opening speed so that the safety feature is not activated. 1 lowest speed. 1...10 Opening direction: Final speed (Sealed) Adjust the final speed in order so that the door stops at the open position 1 lowest speed.
  • Page 11 CONTROL POINTS DOOR FORCES Lock-up force (Sealed) The operator keeps the door closed at preset force for 1 second following which this reduced to half of the preset 0 ... 10 value. Value 0 ~ no lock-up force, 10 highest. Pressure closed before opening The operator drives the door against the closed position for a preset value of 1 second.
  • Page 12 CONTROL POINTS SAFETY FEATURE Closing direction: Safety feature Selection of safety feature operation in closing direction 0= the door stops 1= the door stops and reopens. Operating zone for safety sensor The fixed obstacles in safety sensor zone can be excluded by adjusting the area smaller than the door open position.
  • Page 13: Internal Connections

    INTERNAL CONNECTIONS 123456789 950640 Fire adapter -.- .. - --- " @l ••• AUTO blacJc MANUAL OPEN bl"" Pulse counter , ••• black bIad< whI'. ••• ""'do , ••• blue Ground __ .. _ ... _ .._::.1 Mains s 'leh TBOOmA &...
  • Page 14: External Connections

    EXTERNAL CONNECTIONS 5equendng led-unit jumpers Sequencing (pages 25-26) •• Safely sensor (page 27) Impulse Inslde (page 28) Impulse outside (page 28) Locking circuit (page 29) Lock control relay + 12VDC + 24 l_ ..•.. Max. output 12 V DCI 0.5 A or 24 V DC I 0.8 A Lock control relay Contacts ratings: Max power 0,8A130V resistive.
  • Page 15 FIRE ADAPTER POWER SMOKE DETECTOR ALARM (N.CJN.O. relay) NO C NO C Take jumper away if smoke detectors are used. 950640 Fire adapter AUTO black MANUAL OPEN JUMPERS: Fire detector input: If the jumper is on. the adapter requires N.O output from the fire detector (otherwise N.C) The spring direction:...