Sidelite Removal Procedure

Top View
Security Set Screw
Top Pivot Pin
(Spring Loaded)
Pivot Security Set Screw

US23-2101-02 Rev A
1. Loosen Pivot Security set screw.
2. Breakout sidelite to gain access to Top Pivot Pin located in
the slot next to the pivot shaft.
3. Using a ¼" Allen Wrench key, and while supporting the
sidelite, push down on the spring loaded Top Pivot Pin to
disengage pivot.
4. Tilt the top of door away from the header.
5. Lift the panel off from bottom pivot.