4. Check the position of the header; adjust side-to-side and
front-to-back as needed, then clamp or temporarily fasten the
assembly in place at the top of each jamb.
Note!
ICU Headers are not self-supporting and require overhead
support for proper operation. Anchor holes will be pre-drilled at
the factory in header to aid in installation.
5. Starting at the center of the header and working towards
each jamb, partially install anchors through each pre-drilled
installation hole.
6. Remove temporary fasteners and/or clamps from jambs.
7. Re-check header for level, insert shims as required and
tighten header anchors.
Note!
It may be necessary to leave a slight gap between the opening
and header so that the installation anchor can draw the header
up to a level condition.
8. Check each jamb for plumb and square, insert shims as
required and install anchors.
9. Recheck all members for level, plumb and square, making
adjustments as required.

Fitting the Floor Track

The following steps explain how to install the floor mounted
guide tracks for fixed sidelite applications.
Note!
It is important that the floor guide track be installed level to
prevent derailment of the floor guide system when the door is
swung out.
1. Inspect the floor for conditions such as high and low spots
that can cause the track to twist and rock. High spots (such
as small rocks) should be removed. Check floor to ensure
that it is level.
2. Using a chalk line, snap a reference line from jamb–to-jamb
on the side where the track is being installed.