Adjustment Screw
16. The tension for the Ball Catch and Ball Detent are adjustable
as required by local egress codes. The tension is not to
exceed 50 lbs. breakout force. To adjust, use a 10 mm
wrench on wrench flats to turn the Detent Assembly. To
increase tension on the Ball Catch, rotate CCW. To decrease
the tension, rotate CW.
Note!
If the glass has not been previously installed, recheck ball catch
alignment after glazing and readjust as required.