6.8 Connection of EG-3000
Follow the instructions given below for connecting EG-3000 for displaying demo
pictures. But GAIN and STC cannot be adjusted.
Adjustment of video signals
Make adjustments of R401 so that the level of TP58 on the SPU board achieves 2Vp-p.
See p.4-81.
Setting:
1. Select "EG" in "[Menu] -> 0 -> 8 -> 2:DEMO ECHO".
2. Select a type other than IMO type in "[Menu] -> 0 -> 4 -> 7:TYPE".
3. Select "GPS1" in "1.NAV AID" of the [OS POSN] box menu.
4. Select "MANUAL" in "1.SPEED" in the [SPEED] box menu and enter the ship
speed in this menu.
B.P SW
EG-3000
(NH-11P)
EG NAV
(XH-5P)
EG AD-10
(XH-4P)
360 deg.
OP VIDEO IN
1
2
3
4
OP BP IN
5
OP HD IN
6
7
8
9
10
11
NAV-A
1
NAV-B
2
3
4
5
1
2
3
4
Fig. 6.8.1 Connection of EG-3000